— Entry only at one inverter. All other inverters connected to the network are blocked
— With the number allocation completed, the inverter switches to the Date screen
Date
Key
Function

Increment or decrement present digit

Select next or previous digit
OK
Accept date setting
Time
Key
Function

Increment or decrement present digit

Select next or previous digit
OK
Accept time setting
Note:
It is possible to connect monitoring devices to the EIA485 bus, for example the Webmaster. If the Webmaster is
connected to the internet, it obtains time and date from a time server. If, during a network scan, the inverter has
recognized a monitoring device with own date and time settings, the inverter accepts these settings as default
settings.
Note:
Changing date or time can result in overwriting saved data or cause gaps in data recording.
User's Guide THEIA S String Inverters
357100.013, Issue 2.0, 2010 Aug