Daikin FTKS20D3VMW Service Manual page 227

Super multi nx
Table of Contents

Advertisement

Instruction
Regarding wiring
All wiring must be performed by an authorized
electrician.
To do wiring, ask your dealer. Never do it by yourself.
Make sure that a separate power supply circuit is
provided for this air conditioner and that all electrical
work is carried out by qualified personnel according to
local laws and regulations.
Pay attention to running noises, too
Are the following places selected?
a. A place that can sufficiently withstand the weight of the
air conditioner with less running noises and vibrations.
b. A place where the hot wind discharged from the air
outlet of outdoor unit and the running noises.
Are you sure that there are no obstacles near the air
outlet of the outdoor unit?
Such obstacles may result in declined performance and
increased running noises.
If abnormal noises occur in use, stop the operation of
the air conditioner, and then cunsult your dealer or our
service station.
Regarding drainage of drain piping
Is the drain piping executed to perform complete
drainage?
If proper drainage is not carried out from the outdoor drain
pipes during air-conditioning operation, chances are that
dust and dirt are clogged in the pipe. This may result in a
water leakage from the indoor unit. Under such
circumstances, stop the operation of the air conditioner,
and then consult your dealer or our service station.
5. NAME AND FUNCTION OF EACH SWITCH
AND DISPLAY ON THE REMOTE CONTROL
Refer to figure 1 on page [1]
ON/OFF BUTTON
Press the button and the system will start.
1
Press the button again and the system will
stop.
OPERATION LAMP (RED)
2
The lamp lights up during operation.
DISPLAY "
CENTRALIZED CONTROL)
3
When this display shows, the system is
UNDER CENTRALIZED CONTROL.
DISPLAY "
(VENTILATION/AIR CLEANING)
4
This display shows that the total heat
exchange and the air cleaning unit are in
operation (These are optional accessories).
216
" (UNDER
" "
" "
" "
"
DISPLAY "
" "
" "
(OPERATION MODE)
5
This display shows the current OPERATION
MODE. For cooling only type, "
and "
" (Heating) are not installed.
DISPLAY "
" (INSPECTION/TEST
TEST
OPERATION)
6
When the INSPECTION/TEST OPERATION
BUTTON is pressed, the display shows the
system mode is in.
hr
DISPLAY "
" (PROGRAMMED TIME)
hr
7
This display shows the PROGRAMMED
TIME of the system start or stop.
DISPLAY "
" (SET TEMPERATURE)
C
8
This display shows the set temperature.
DISPLAY "
" (FAN SPEED)
9
This display shows the set fan speed.
DISPLAY "
" (AIR FLOW FLAP)
10
Refer to "AIR FLOW DIRECTION ADJUST".
DISPLAY "
" (TIME TO CLEAN AIR
11
FIL-TER)
Refer to "HOW TO CLEAN THE AIR FILTER".
DISPLAY "
" (DEFROST)
12
Refer to "DEFROST OPERATION".
NON-FUNCTIONING DISPLAY
If that particular function is not available,
pressing the button may display the words
"NOT AVAILABLE" for a few seconds.
13
When running multiple units simultaneously
The "NOT AVAILABLE" message will only be
appear if none of the indoor units is equipped
with the function. If even one unit is equipped
with the function, the display will not appear.
TIMER MODE START/STOP BUTTON
14
Refer to "PROGRAM TIMER OPERATION".
TIMER ON/OFF BUTTON
15
Refer to "PROGRAM TIMER OPERATION".
INSPECTION/TEST OPERATION BUTTON
16
This button is used only by qualified service
persons for maintenance purposes.
PROGRAMMING TIME BUTTON
17
Use this button for programming "START and/
or STOP" time.
TEMPERATURE SETTING BUTTON
18
Use this button for SETTING TEMPERA-
TURE.
FILTER SIGN RESET BUTTON
19
Refer to HOW TO CLEAN THE AIR FILTER.
SiENBE12-713
" "
" "
"
" (Auto)
System Configuration

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents