Deutsch Split-Baureihe R410A Manuel d’installation Français Série split R410A Montagehandleiding Nederlands R410A Split-systeem Manual de instalación INVERTER Models Español Serie Split R410A FTXS50FV1B FTKS50FV1B Manuale d’installazione FTXS60FV1B FTKS60FV1B Italiano Serie Multiambienti R410A FTXS71FV1B FTKS71FV1B Εγχειρßδιο εγκατÜστασηò FTX50GV1B ΕλληνικÜ διαιροýìενηò σειρÜò R410A FTX60GV1B Manual de Instalação...
Safety Precautions • Read these Safety Precautions carefully to ensure correct installation. • This manual classifies the precautions into WARNING and CAUTION. Be sure to follow all the precautions below: they are all important for ensuring safety. WARNING....Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury. CAUTION....Failure to follow any of CAUTION may result in grave consequences in some cases.
Installation Tips Removing and installing front grille. mark area Upper hook (3 locations) • Removal method 1) Remove front panel to remove the air filter. 2) Remove the front grille. (3 screws) 3) In front of the mark of the front grille, there are 3 upper hooks. Lightly pull the front grille toward you with one hand, and push down on the hooks with the fingers Upper hook Lightly pull the front...
Indoor Unit Installation Drawings How to attach the indoor unit. Hook the claws of the bottom frame A Mounting to the mounting plate. plate If the claws are difficult to hook, remove the front grille. Clip How to remove the indoor unit. Bottom frame Push up the marked area (at the lower part of the front grille) to...
Indoor Unit Installation Installing the mounting plate. • The mounting plate should be installed on a wall which can support the weight of the indoor unit. 1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the boring points on the wall.
Boring a wall hole and installing wall embedded pipe. • For walls containing metal frame or metal board, be sure to use a wall embedded pipe and wall cover in the feed-through hole to prevent possible heat, electrical shock, or fire. Inside Outside •...
Indoor Unit Installation 3-2. Left-Side, Left-Back, or Left-Bottom Piping Remove pipe 1) Attach the drain hose to the underside of the refrigerant pipes port cover here for left- with adhesive vinyl tape. side piping Left-side piping Left-back Remove pipe port cover here for left-bottom piping piping Left-bottom piping 2) Be sure to connect the drain hose to the drain port in place of a...
Wiring. ith a Multi indoor unit , install as described in the installation manual supplied with the Multi outdoor unit. 1) Strip wire ends (15mm). 2) Match wire colours with terminal numbers on indoor and outdoor unit’s terminal blocks and firmly screw wires to the corre- sponding terminals.
Indoor Unit Installation Drain piping. The drain hose should be inclined downward. 1) Connect the drain hose, as described right. No trap is permitted. Do not put the end of the hose in water. 2) Remove the air filters and pour some water into the drain pan to check the water flows smoothly.
Refrigerant piping. CAUTION 1) Use the flare nut fixed to the main unit. (To prevent cracking of the flare nut by aged deterioration.) 2) To prevent gas leakage, apply refrigeration oil only to the inner surface of the flare. (Use refrigeration oil for R410A.) 3) Use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and gas leakage.
Trial Operation and Testing Trial operation and testing. 1-1 Measure the supply voltage and make sure that it falls in the specified range. 1-2 Trial operation should be carried out in either cooling or heating mode. ■ For Heat pump •...