Daikin FTKS20D3VMW Service Manual page 177

Super multi nx
Table of Contents

Advertisement

Instruction
Check
Check that the base, stand and other fittings of the outdoor unit are not decayed or corroded.
Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit.
Check that the drain comes smoothly out of the drain hose during COOL or DRY operation.
• If no drain water is seen, water may be leaking from the indoor unit. Stop operation and consult the service shop if this is the case.
" Before a long idle period
1. Operate the "FAN only" for several hours on a fine day to dry out the inside.
2. After operation stops, turn off the breaker for the room air conditioner.
3. Clean the air filters and set them again.
4. Take out batteries from the remote control.
NOTES
Operation with dirty filters:
(1) cannot deodorize the air.
(3) results in poor heating or cooling.
To order Titanium Apatite Photocatalytic Air-Purifying Filter contact to the service shop there you bought the air
conditioner.
Dispose of old filters as non-flammable waste.
Titanium Apatite Photocatalystic Air-Purifying Filter (without frame) 1
set
166
Press "MODE" button and select "FAN" operation.
Press "ON/OFF" button and start operation.
When a multi outdoor unit is connected, make sure the heating operation is not used at the
other room before you use the fan operation.
(2) cannot clean the air.
(4) may cause odour.
Item
SiENBE12-713
Part No.
KAF952B42
System Configuration

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents