[ IX Troubleshooting ]

Sensors and item code list

Item
MAIN circuit
Error history 1
Error history 1 details (Inverter error)
Error history 1/Occurrence time
Error history 2
Error history 2 details (Inverter error)
Error history 2/Occurrence time
Error history 3
Error history 3 details (Inverter error)
Error history 3/Occurrence time
Error history 4
Error history 4 details (Inverter error)
Error history 4/Occurrence time
Error history 5
Error history 5 details (Inverter error)
Error history 5/Occurrence time
Error history 6
Error history 6 details (Inverter error)
Error history 6/Occurrence time
Inlet water temp (Twi )
Outlet water temperature (Two)
Discharge refrigerant 1 TH1
Suction refrigerant 1 TH2
Shell temperature 1 TH3
Air-side heat exchanger inlet 1 TH4
Outside temperature TH9
Inlet water temperature 1 TH10
Outlet water temperature 1 TH11 Outlet water temperature 2 TH13
Representative water temperature 1 TH14
Representative water temperature 2 TH15
High pressure 1 HP1
Low pressure 1 LP1
Heatsink temperature(THHS)
Water temperature setting using an external
analog input (4-20 mA Current input)
I u(U-phase current)(Compressor)
I w(W-phase current)(Compressor)
I dc(Bus current)(Compressor)
Vdc(Bus voltage)(Compressor)
I u(U-phase current)(Fan)
I w(W-phase current)(Fan)
I dc(Bus current)(Fan)
V dc(Bus voltage)(Fan)
Suction SH (target)
Compressor frequency (actual frequency)
Suction SH
Shell bottom SH
Operating frequency of the fan (actual frequency)
Opening of the LEV on the main circuit
Injection LEV opening
Discharge SH (target)
Discharge SH
Target water temperature
Water temperature setting using an external analog input (0-10 V or 2-10 V Voltage input)
Water temperature setting using an external analog input (1-5 V Voltage input)
(Note1) Refer to the section "1. Checking the error history" for further information. (Page 105)
(Note2) Codes c01 through C11 and c14 indicate temperature sensors.
(Note3) Codes c12 and c13 indicate pressure sensors.
(Note4) Codes c15 through c18 and c20 through 22 indicate current sensors.
(Note5) Codes c19 and c23 indicate voltage sensors.
(Note6) Codes c24, c31, and c33 indicate target values.
(Note7) Code c25 indicates compressor's operating frequency.
(Note8) Code c26 indicates superheat that was calculated based on the low pressure and suction refrigerant temperature.
(Note9) Code c27 indicates superheat that was calculated based on the low pressure and shell temperature.
(Note10) Code c28 indicates the operating frequency of the fan.
(Note11) Codes c29 and c30 indicate the degree of LEV opening.
(Note12) Code c32 indicates superheat that was calculated based on high pressure and discharge refrigerant temperature.
(Note13) When the input type is selected. When the input type is not selected = 0.
(Note14) c35 and c36 show the external analog input values (water temperature settings)
HWE10060
Item
code
SUB circuit
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Inlet water temp 2 TH12
c01
c02
Discharge refrigerant 2 TH5
c03
Suction refrigerant 2 TH6
c04
Shell temperature 2 TH7
c05
Air-side heat exchanger inlet 2 TH8
c06
Outside temperature TH9
c07
Inlet water temperature 2 TH12
c08
c09
-
c10
-
c11
High pressure 2 HP2
c12
Low pressure 2 LP2
c13
c14
-
c15
c16
c17
c18
c19
c20
c21
c22
c23
c24
c25
c26
c27
c28
c29
c30
c31
c32
c33
c35
c36
Unit and circuit type
LED display
Main unit
MAIN circuit SUB circuit MAIN circuit SUB circuit
Error Code
Error Code
Time
Error Code
Error Code
Time
Error Code
Error Code
Time
Error Code
Error Code
Time
Error Code
Error Code
Time
Error Code
Error Code
Time
First decimal place
First decimal place
First decimal place
First decimal place
First decimal place
First decimal place
First decimal place
First decimal place
First decimal place
First decimal place
Fixed to 0 Fixed to 0 Fixed to 0
First decimal place
Fixed to 0 Fixed to 0 Fixed to 0
Second decimal place
Second decimal place
First decimal place
First decimal place (Note13) Fixed to 0 Fixed to 0 Fixed to 0
First decimal place
First decimal place
First decimal place
Integer
First decimal place
First decimal place
First decimal place
Integer
First decimal place
Integer
First decimal place
First decimal place
Integer
Integer
Integer
First decimal place
First decimal place
First decimal place
First decimal place (Note13) Fixed to 0 Fixed to 0 Fixed to 0
First decimal place (Note13) Fixed to 0 Fixed to 0 Fixed to 0
- 108 -
Sub unit
Notes
(Note1)
(Note2)
(Note2)
(Note2)
(Note2)
(Note2)
(Note2)
(Note2)
(Note2)
(Note2)
(Note2)
(Note2)
(Note3)
(Note3)
(Note2)
(Note4)
(Note4)
(Note4)
(Note4)
(Note5)
(Note4)
(Note4)
(Note4)
(Note5)
(Note6)
(Note7)
(Note8)
(Note9)
(Note10)
(Note11)
(Note11)
(Note6)
(Note12)
(Note6)
(Note14)
(Note14)
GB

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents