MODE
Loc 17 = 1
MODE
AUTO
Loc 17 = 2
MODE
Loc 17 = 3
MODE
Loc 17 = 4
MODE
Loc 17 = 5
MODE
AUTO
Loc 17 = 6
ON/OFF
Button pressed and held for 3 sec
Button pressed once
par. description
min max def UOM type ind. R/W note
-
ON/OFF
0
1
OFF
ON
Clock button (2)
The button is used to set:
•
The time bands.
•
The clock
Fig. 4.c.b
Key:
Select band number
Select HOUR, MINUTES and ON/OFF/TEMP fi elds
Set the value of the fi eldsi
HEAT
HEAT
HEAT
HEAT
0
-
D
6
R/W
COOL
COOL
COOL
COOL
Terminal time bands
The terminal can save up to two daily events with the automatic
changeover of the ambient settings at set times.
Fig. 4.c.c
Key:
enter time band setting mode by pressing once
Band 1 can now be programmed, with hour digits fl ashing
1.
Enter the start hours for band 1 using the UP and DOWN buttons
2.
Press
to select MINUTES
3.
Enter the start minutes for band 1 using the UP and DOWN buttons
4.
Press
to select ON/OFF/TEMP
5.
Enter the action of band 1 using the UP and DOWN buttons
•
OFF
•
ON
•
Temperature set point: 8 °C to 32 °C
6.
Press
to select band 2 and repeat steps 1 to 5
To exit the time band setting mode:
•
by time around 30 s after the last button was pressed
•
manually by pressing
The enabling of the time bands is indicated in normal operation by the
symbol
and the number of the band that is active at that time.
Note: from when programming until the expiry of the fi rst band,
only the symbol
without indicating the number of the
active band.
17
easy way ARIA +030220841 - rel. 1.0 - 26.10.2007
GB
FAN
DRY
Tab. 4.c
Fig. 4.c.d