Specifications; Specification - Kenmore 795.78733.804 Service Manual

Compressor 956 btu/hr
Table of Contents

Advertisement

1. SPECIFICATIONS

1-1 DISCONNECT POWER CORD BEFORE
SERVICING
IMPORTANT – RECONNECT ALL
GROUNDING DEVICES
All parts of this appliance capable of conducting electrical
current are grounded. If grounding wires, screws, straps,
clips, nuts or washers used to complete a path to ground
are removed for service, they must be returned to their
original position and properly fastened.
1-2 IMPORTANT NOTICE
This information is intended for use by individuals
possessing adequate backgrounds of electrical, electronic
and mechanical experience. Any attempt to repair a major
appliance may result in personal injury and property
damage. The manufacturer or seller cannot be responsible
for the interpretation of this information, nor can it assume
any liability in connection with its use.
1-3 ELECTRICAL SPECIFICATIONS
Temperature Control (F
Defrost Control......Total Comp Running Time: 7 hrs~50 hrs
Defrost Thermostat .......................................................46°F
Electrical Rating : 115VAC, 60Hz.................................7.2 A
Maximum Current Leakage.......................................0.5 mA
Maximum Ground Path Resistance ....................0.14 Ohms
Energy Consumption ............................25 cu.ft. 684 kWh/yr
1-4 NO LOAD PERFORMANCE
CONTROL POSITION: MID/MID
And Ambient of: ..................70°F..................................90°F
Fresh Food, °F ....................33°F to 41°F.........33°F to 41°F
Frozen Food, °F ..................-4°F to +4°F ..........-4°F to +4°F
Percent Running Time ........35%-45% .................50°F-70°F
1-5 REFRIGERATION SYSTEM
Minimum Compressor Capacity Vacuum ............... 21 MIN.
Minimum Equalized Pressure
@ 70°F ....................................................... 49 PSIG
@ 90°F ....................................................... 56 PSIG
Refrigerant R134a .................................................. 5.11 oz.
Compressor ..................................................... 956 BTU/hr
1-6 INSTALLATION
Clearance must be provided at top, sides and rear of the
refrigerator for air circulation.
AT TOP ......................................................................... 2 in
AT SIDES ...................................................................... 1 in
AT REAR ...................................................................... 1 in
1-7 REPLACEMENT PARTS
Relay..............................................................6748C-0004D
Overload ........................................................6750C-0004R
Defrost Thermostat........................................6615JB2005H
Defrost Heater ...............................................5300JK1005D
Evaporator Fan Motor....................................4681JB1027C
Capacitor (Running) ...................................0CKZZJB2012K
Compressor (Hi-Side)
Evaporator (Lo-Side)......................................5421JJ1003B
Condenser....................................................ACG36653801
Dryer..............................................................5851JA2008U
Condenser Fan Motor ...................................4681JB1029D
Temperature Control ...........................ABQ56655301(STS)
Dispenser Control ...............................ACQ67140901(STS)
Main Control .................................................EBR41956410
Ice Fan Motor ................................................4681JB1029E
) ...-6°F to +8°F
1-8 AIR FLOW / CIRCULATION D'AIR
- 3 -
795.78733.804 795.78743.804
795.78739.804 795.78749.804
ABQ56655303(WB)
ACQ67140903(WB)
EVAPORTOR FAN MOTOR
CONDENSER FAN MOTOR
Glide'N'Serve
25 cuft
(0CKZZJB2014B)
(0CKZZJB2012H)
TCA31748001
ICE
ROOM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

795.78739.804795.78743.804795.78749.804

Table of Contents