Kenmore 795.78733.804 Service Manual page 36

Compressor 956 btu/hr
Table of Contents

Advertisement

6-11. Troubleshooting With Error
Freezer Sensor Error
Is Er-FS
displayed?
Yes
Is the connection loose?
CON6
No
Power Off
Tip : To protection of MICOM
CON6
BL
11
Main PWB
BL
12
Wiring diagram
Reconnect
Yes
- 36 -
F-Sensor
Disconnect CON6 and measure
the value. Is resistance value
between pins 11 & 12 of CON6
as below? (BL to BL)
pin12
pin11
CON6
Test Point
Result
Pin11 to pin12
1.4 ~ 120 k½
Yes
Reconnect CON6 and Power ON
If the ER-FS appears, Replace
the main PWB. Otherwise,
explain to the customer!
Replace
No
F
-sensor
(Position
No : 610C)