Water Valve Disassembly Method; Fan And Fan Motor Disassembly Method - Kenmore 795.78733.804 Service Manual

Compressor 956 btu/hr
Table of Contents

Advertisement

3-17. WATER VALVE DISASSEMBLY METHOD

1) Turn off the water. Then separate the water line from the
valve.
2). Separate the Mechanical Cover and Valve Screw.
Mechanical Cover
3) Separate the housing and pull out the valve.
Housing
4) Lay a dry towel on the floor and get ready to spill water
from the water filter. Pull out the Cilp. Then press te
collet to separate the tube from the connector and pour
out the water until emptied.
Tube
Insert Line
Collet
Clip
- 20 -
3-18. FAN AND FAN MOTOR DISASSEMBLY
METHOD
1) Using a short screwdriver, loosen one SCREW in
DRAIN PIPE ASSEMBLY and one connected to the
MOTOR COVER.
2) Pull and separate the FAN ASSEMBLY and MOTOR
turning counterclockwise based on the MOTOR SHAFT.
The assembly is in the reverse order of the disassembly
and take special care for the following details.
1. Be careful not to bend the tube during assembly.
2. Press the WATER DISPENSER button until water pours
out and check for leakage in the CONNECTOR TUBE (It
differs by the water pressure but usually takes about 2
minutes until water pours out.)
MOTOR COVER
FAN ASSEMBLY
MOTOR

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

795.78739.804795.78743.804795.78749.804

Table of Contents