Kenmore 795.78733.804 Service Manual page 40

Compressor 956 btu/hr
Table of Contents

Advertisement

Defrost Heater Error
D-Sensor
BO
1
6
BO
2
7
Housing-A
Is Er-dH
displayed?
Yes
Is the connection loose?
CON6
CON3
No
BO
10
7
Main
BO
4
8
PWB
CON6
CON3
Wiring diagram
Yes
Reconnect
- 40 -
BL
6
1
BN
WH
7
2
BL
BK
1
2
BK
3
Enter the TEST 3 MODE
Is the voltage value
between pins 10(WH) and
4 (BL) of CON3 115 V AC?
CON3
pin4 BL
pin10 WH
Relay operation
Relay operation
Relay operation
Relay operation
Test Point
Result
pin4 To pin10
115V
Yes
Reset TEST3 MODE(Normal)
Is the voltage value between
pins 10 (WH) and 4 (BL) of
CON3 0 V AC?
CON3
pin4 BL
pin10 WH
Relay Open
Relay Open
Relay Open
Relay Open
Test Point
Result
Reset/Norm OP
0 ~ 2 V
Yes
FUSE-M
DEF-Heater
Replace
No
MAIN PWB
(Position No:
500A)
Replace
MAIN PWB
No
(Position No:
500A)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

795.78739.804795.78743.804795.78749.804

Table of Contents