Code
6400
7000
7410
Downloaded from
www.Manualslib.com
Contents
Zero cross signal error
The ZCROSS signal does not reach the
engine PWB for more than 2 s.
Toner motor lock error
A motor over-current signal is detected
continuously for 5 seconds since the
toner motor is activated.
Drum unit non- installing error
The drum unit is not installed or not
installed properly.
The drum PWB EEPROM does not com-
municate normally.
manuals search engine
Remarks
Causes
Check procedures/corrective measures
Defective harness
Reinsert the connector. Also check for conti-
between connect-L
nuity within the connector harness. If none,
PWB (YC8) and
remedy or replace the harness.
engine PWB (YC3),
or improper connec-
tor insertion.
Defective connec-
Reinsert the connector.
tion between
power source unit
(YC103) and con-
nect-L PWB (YC1).
Defective power
Replace the power source unit (See page 1-
source unit.
5-38).
Defective engine
Replace the engine PWB (See page 1-5-
PWB.
25).
Lump of toner
Replace the toner container.
inside toner con-
tainer.
Defective toner
Replace the developing unit (See page 1-5-
replenishment
11).
drive system.
Defective toner
Replace the developing unit (See page 1-5-
motor.
11).
Defective engine
Replace the engine PWB (See page 1-5-
PWB.
25).
The drum unit is
Install the drum unit (See page 1-5-12).
not installed.
Defective connec-
Check the connection of connectors drum
tion drum PWB
PWB (YC1) and connect-L PWB (YC3).
(YC1) and con-
(See page 1-4-10, refer to figure 1-4-5)
nect-L PWB (YC3).
Defective drum
Replace the drum unit (See page 1-5-12).
PWB EEPROM.
Defective engine
Replace the engine PWB (See page 1-5-25).
PWB.