Fault code No.
46
Diagnostic monitoring
code No.
Order Item/components and probable cause
1
Connected state of connector
G
Wire harness ECU coupler
2
Faulty battery.
3
Malfunction of the rectifier/regulator
4
Open or short circuit in the wire harness.
Fault code No.
50
Diagnostic monitoring
code No.
Order Item/components and probable cause
1
Malfunction in ECU
Symptom
Power supply to the FI system relay is not normal.
Check or maintenance job
G
G
G
G
Refer
CHARGING THE BATTERY" on
page 8-68.
G
G
Repair or replace if there is an open
or short circuit.
G
(Red–Red)
G
(Brown–Brown)
G
(Red/White–Red/White)
Faulty ECU memory. (When this malfunction is detected in the
Symptom
ECU, the fault code number might not appear on the meter.)
Check or maintenance job
G
8-52
FUEL INJECTION SYSTEM
Check the coupler for any pins that
may have pulled out.
Check the locking condition of the
coupler.
If there is a malfunction, repair it
and connect it securely.
Replace or charge the battery.
to
"CHECKING
Replace if defective.
"CHARGING SYSTEM"
Refer to
on page 8-11
.
Between battery and main switch.
Between main switch and fuse
(ignition)
Between fuse (ignition) and ECU
Replace the ECU.
Reinstatement
method
Starting the
engine and oper-
ating it at idle.
AND
Reinstatement
method
Turning the main
switch ON

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wr250x

Table of Contents