User enable/disable options:
Confidence beep, latching alarm, pass code protect,
automatic O
calibration at startup, automatic pump test at
2
startup (supplied by manufacturer with these options
disabled); set calibration due date; set STEL calculation
period, set span concentration values, adjust clock calendar,
language selection, and sensor disable.
Approved batteries:
Black & Decker VersaPak™ NiCd (VP-100) rechargeable
battery
Black & Decker VersaPak™ NiMH (VP-110) rechargeable
battery
Area
NiCd (VP-100)
North America
T4 (131.6°C)
Europe
T4
Australia
T3
Battery charger: Black & Decker VersaPak™ VP130
charger
Battery operating time:
NiCd: 8 hours
NiMH: 10 hours
58
NiMH (VP-110)
T4 (134.6°C)
T3 (184°C)
T2 (213°C)
First-time charge:
NiCd: 6 hours for two batteries
NiMH: 12 hours for two batteries
Normal charge:
NiCd: 3-4 hours for two batteries
NiMH: 12 hours for two batteries
Approvals:
Approved by CSA to both U.S. and Canadian Standards
Approved: Class I, Division 1, Group A, B, C, and D;
Class I, Zone 0, Group IIC
ATEX:
CE 0539 g II 2G
LCIE 02 ATEX 6103 X
EEx ia d IIC 184°C
AUS: Ex ia s IIB Ambient 40°C
** Oxygen alarm setpoints for user selectable low and high
alarms are in the 0-25.5% range.

Advertisement