Section 4.1

Power Supply Specifications

Power
Minimum Input
Supply Type
54 VDC
a
(T) denotes time-delay fuse
Section 4.2

PoE Power Supply Specifications

The RUGGEDCOM RS900GP adheres to the following power output and IEEE specifications depending on the
input voltage supplied to the device.
Power Supply Specifications
Maximum Input
45 VDC
57 VDC
Power In
51-57 VDC
45-57 VDC
Fuse Rating
Isolation
a
6.3A (T)
1.5 kVDC
50-57 VDC, 30 W per Port Maximum (IEEE 302.at)
44-57 VDC, 15 W per Port Maximum (IEEE 302.af)
Technical Specifications
Maximum
Maximum Power
Combined
Consumption
Power Output
at PoE Ports
15 W
273 W
Power Out