Chapter 4
Technical Specifications
Section 4.3
Failsafe Alarm Relay Specifications
NOTE
The following specifications are for Class-2 circuits only.
Maximum Switching Voltage
30 VDC
125 VDC
125 VAC
220 VDC
250 VAC
Section 4.4
Copper Ethernet Port Specifications
The following details specifications for all standard and optional fixed copper Ethernet ports that can be ordered
with the RUGGEDCOM RS900GP. For more information about the SFP ports, refer to
Ethernet
Ports".
NOTE
For specifications on optional copper Small Form-Factor Pluggable (SFP) ports, refer to
"SFP Optic Ethernet Port
NOTE
• Maximum segment length is greatly dependent on factors such as fiber quality, and the number
of patches and splices. Consult a Siemens Sales associate when determining maximum segment
distances.
• All optical power numbers are listed as dBm averages.
• F51 transceivers are rated for -40 to 85 °C (-40 to 185 °F).
Connector
RJ-45 (PoE
and Non-PoE)
micro-D
b
Auto-Negotiating.
c
Shielded or unshielded.
d
Auto-crossover and auto-polarity.
e
Typical distance. Dependent on the number of connectors and splices.
24
Rated Switching Current
Specifications".
b
Duplex
Cable Type
FDX/HDX
> CAT-5
FDX/HDX
> CAT-5
2 A, 60 W
0.24 A, 30 W
0.5 A, 62.5 W
0.24 A, 60 W
0.25 A, 62.5 W
c
d
Wiring Standard
TIA/EIA T568A/B
TIA/EIA T568A/B
RUGGEDCOM RS900GP
Installation Guide
Isolation
1500 V
for 1 minute
rms
Section 3.2, "Copper
Section 4.6,
Maximum
Isolation
e
Distance
100 m (328 ft)
1.5 kV
100 m (328 ft)
1.5 kV
Failsafe Alarm Relay Specifications