Panasonic WJ-SX650 Operating Instructions Manual page 92

Wj-sx650 series matrix switcher operating instructions wj-sx650
Hide thumbs Also See for WJ-SX650:
Table of Contents

Advertisement

Problem
Auto tracking ended before
the end time of camera event
setting.
Alarm event does not occur.
The image of camera associ-
ated with the alarm event was
not recorded.
The status before the alarm
occurrence is not recovered,
even though the alarm event
is reset.
Alarm modes of connected
devices are not reset even
after the unit is powered off.
Cannot open SETUP MENU
of the unit.
92
Check item and remedy
• Check if another camera event is not set for the camera.
• Check if the alarm input signal setting is ON in ALARM of
SETUP MENU.
• Check if the alarm event has been set.
Check if the deactivation period is scheduled for the alarm
event. (Check the alarm schedule setting.)
• Check if the alarm is not suspended and SETUP MENU is
not open on the associated monitor.
Check the connection and settings between the recorder and
the unit.
Recording follows the recorder settings.
Check the event recording setting of recorder.
If an operator has activated a group sequence before the
alarm occurrence, and another operator reset the alarm or
performed operations on the monitor associated with the
group sequence, the status before the alarm occurrence is
not recovered.
• When you power off the unit, the alarm mode activated for
the unit is reset, but the alarm modes for the connected
devices are not reset. Power on the unit again, and perform
alarm reset.
• You cannot open SETUP MENU when another operator is
opening it.
• SETUP MENU cannot be displayed on a monitor associated
with an active alarm.
Reference
35
86
29
90
16, 83
32

Advertisement

Table of Contents
loading

Table of Contents