SYSTEM CONTROLLER
CONTROLLER NO.: 4
Line termination: ON
● PS·Data Mode Connection
To apply the PS·Data mode, connect the system controllers
as follows.
1. Connect the system controllers to the DATA 1 port of
Video Output Board 1.
Notes:
• In the factory default, the DATA 1 port is set for the ter-
minal mode connection. To apply the PS·Data mode
connection, perform the DATA port settings in SETUP
MENU (refer to p. 90) or WJ-SX650 Series Administrator
Console.
• Both of terminal mode and PS·Data system controllers
cannot be connected to the same DATA port.
• DATA 1 port of Video Output Board 2 cannot be set for
the PS·Data connection.
• Up to 4 system controllers can be connected in the
daisy chain. For system controllers in the daisy chain
connection, operator registration is not available. (The
same operator setting is applied for all the system con-
trollers in the PS·Data daisy chain.)
2. Set the MODE switch of DATA ports connected to the
system controllers to ON. (Switch #2: ON)
3. Set the system controllers to the PS·Data mode. (Refer
to the operating instructions of system controllers.)
DATA 4
DATA 3
DATA 2
DATA 1
Video Output Board 2
HDR4/TMNL8
HDR3/TMNL7
TMNL6
TMNL5
Video Output Board 1
HDR2/TMNL4
HDR1/TMNL3
TMNL2
TMNL1/PS DATA
16
15
14
13
12
ALARM OUT 2
SYSTEM CONTROLLER
CONTROLLER NO.: 3
CONTROLLER NO.: 2
Line termination: OFF
Line termination: OFF
Daisy chain connection
4
3
2
TERM.ON
TERM.OFF
ON
MODE
MODE
MODE
DATA
MODE
MODE
DATA
11
10
9
8
7
6
5
MONITOR OUT
VS IN
VS OUT
ALARM OUT 1
VS OUT
(THRU)
DATA2
SYSTEM CONTROLLER
SYSTEM CONTROLLER
CONTROLLER NO.: 1
Line termination: OFF
4. Set the line termination of system controllers with the
MODE switches. (Refer to the operating instructions of
system controllers.) In the daisy chain connection, set
the line termination of chain end system controller to
ON. (Switch #5: ON)
5. In the daisy chain connection, set the CONTROLLER
NO. switches of system controllers to 1 to 4. The switch
setting must be different from each other. (Refer to the
operating instructions of system controller for details on
the CONTROLLER NO. switch setting.)
Note: When using system controllers in the PS·Data
mode, camera numbers that can be selected differ
depending on system controller models.
Example:
WV-CU950/650:
WV-CU360C/CJ: 1 to 199
Select the system controller models that are applicable
for your system composition. When using 200 or more
cameras in the PS·Data mode, apply WV-CU950/650.
ON
Line termination:
ON (#2: ON)
1 2
1
OFF
ON
MODE
OUT
EXTENSION 1
IN
TERM.
OUT X-3
4
3
2
1
Video output
OUT X-2
rear boards
Video Output Board 1 Only
SERIAL
OUT X-1
DATA1
SYSTEM CONTROLLER
CONTROLLER NO.: 1
Line termination: ON
1 to 999