!3 VS Output Connector (VS OUT)
Supplies VS output signals to external devices. While !1
is accepting a VS input signal, !3 supplies an output
signal synchronizing the VS input signal. While !1 is not
accepting the VS input signal, !3 supplies an internal
synchronization output signal.

■ Monitor Display Information

The following are the details on terminal mode operations. For PS·Data operations, refer to p.
THE TERMINAL MODE) or the operating instructions of system controllers.
q
w
e
q
Time and Date Information
Current time and date are displayed.
During daylight saving time (summer time), "∗" is dis-
played beside the time.
Aug/02/2005 ∗20:15:56
Example:
Note: While a recorder is being selected, time and date
are not displayed.
w
Monitor Status Information
Monitor number
M01 to 32: Monitor number
Note: During monitor lock, monitor number is highlight-
ed.
Controller number
Displays a device that selects and controls the monitor.
K1-1 to 8-4: Terminal mode system controller
(Example: For K8-4, "8" means the terminal (TMNL)
number and "4" means the controller number of sys-
tem controller.)
PSD: PS·Data mode system controller
PC: PC connected to the SERIAL port
/T001 to 128: Timer event
Sequence number
Displays the active sequence number.
T01 to 32: Tour sequence number
G01 to 32: Group sequence number
Note: During sequence pause, "P" is displayed beside
the sequence number.
!4 Serial Port (SERIAL)
Connects to a PC.
Note: When q is set as Video Output Board 2, r, !1 ,
!2 , !3 , and !4 are not available.
r
e Camera Information
Camera number
C001 to 999: Camera number
R01 to 16: Recorder number
Camera title
Displays the registered camera title.
Camera title setting is performed in "Camera" – "Camera
Title" of WJ-SX650 Series Administrator Console.
r Event Information
TERMINAL001 to 256: Terminal alarm has occurred.
(Example: For TERMINAL001, "001" means the
number of alarm input signal accepted by the
ALARM IN port of video input board.)
CAMERA001 to 099: Camera alarm has occurred.
(Example: For CAMERA001, "001" means the num-
ber of camera supplying an alarm input signal to
the unit.)
RECORDER001 to 999: Recorder alarm has occurred.
(Example: For RECORDER001, "001" means the
number of camera associated with the recorder
supplying an alarm input signal to the unit.)
SERIAL0001 to 1024: Serial alarm has occurred.
(Example: For SERIAL0001, "0001" means the serial
command alarm input number.)
VIDEO LOSS001 to 999: Video loss has occurred.
(Example: For VIDEO LOSS001, "001" means the num-
ber of camera to which video loss has occurred)
SUSPEND: Alarm is suspended.