Panasonic WJ-SX650 Operating Instructions Manual page 46

Wj-sx650 series matrix switcher operating instructions wj-sx650
Hide thumbs Also See for WJ-SX650:
Table of Contents

Advertisement

Tour Sequence 7: Images of LCN 193 to 224 are sequen-
tially switched for two seconds.
Tour Sequence 8: Images of LCN 225 to 256 are sequen-
tially switched for two seconds.
Tour Sequence 9 to 32: No settings
"Group Sequence"
Group Sequence 1: 4 cameras among LCN 1 to 64 are
sequentially switched for 2 seconds on Monitor 1 to 4.
Group Sequence 2: 4 cameras among LCN 65 to 128 are
sequentially switched for 2 seconds on Monitor 5 to 8.
Group Sequence 3: 8 cameras among LCN129 to 256 are
sequentially switched for 2 seconds on Monitor 9 to 16.
Group Sequence 4 to 8: No settings
Group Sequence 9: Spot image of LCN 1 to 16 are dis-
played on Monitor 1 to 16.
Group Sequence 10 to 32: No settings
● Schedule
"Timer Event"
No settings
"Camera Event"
No settings
● Alarm
"Alarm Mode"
Alarm Mode: Sequence* (Dwell Time: 2 sec*)
Auto Reset: 30 sec*
"Level Table"
Item
System
OSD Control
Alarm History Display
System Status Display
Alarm Suspension
Alarm All reset
reset
Alarm ACK, Alarm Individual/
Monitor Reset
Start Tour Sequence
Start Group Sequence
Monitor Lock
Camera Setup
Preset Position Registration
All Cameras Control
Camera Control
Camera Selection
Recorder Setup
Recorder Control
46
Level 1
Level 2
Enabled
Disabled
(Checked)
(Not checked)
Enabled
Enabled
Enabled
Enabled
Enabled
Disabled
Enabled
Disabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Disabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Disabled
Enabled
Enabled
Terminal Alarm: ON (All alarms are N.O.)*
Camera Alarm: OFF*
Recorder Alarm: OFF*
Serial Alarm: OFF*
Video Loss: OFF*
"Alarm Event"
Terminal Alarm 1 to 256: SPOT, LCN 1 to 256, Monitor 1
Camera Alarm 1 to 256:
No settings
Recorder Alarm 1 to 256:
No settings
Video Loss 1 to 256: Monitor 4 (No events)
Serial Alarm 1 to 1024: No settings
"Monitor Display Mode"
Monitor
1 to 16
17 to 24
25 to 32
"Alarm Schedule"
No settings
● Operator
"Operator"
Note: Refer to p.
19
Operator Registration.
PS·Data: User ID: 650
HDR Network Operation: Priority: 1
Level 3
Level 4
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Enabled
Disabled
Enabled
Enabled
Enabled
Enabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Enabled
Disabled
Enabled
Enabled
Disabled
Disabled
Enabled
Disabled
Display Mode
Spot
Tour Sequence
Group Sequence
Level 5
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled

Advertisement