Notes:
• During the alarm acknowledgement (ACK) status (refer
to p. 31), event information is highlighted.
• When two or more alarm events have occurred, "∗" is
displayed beside the event.
• When an alarm occurs and its display mode setting is
OFF (refer to p. 30), "#" is displayed beside the event
information.
• When auto tracking is scheduled for a camera event, "#"
is displayed beside the camera number.
• q to r can be displayed or hidden either altogether or
separately. Refer to p.
Operations for details.
■ System Controller Display
Information
The following are the details on terminal mode operations.
For PS·Data operations, refer to p.
THAN THE TERMINAL MODE) or the operating instructions
of system controllers.
● WV-CU950/650
q
r
q Monitor Number
Mon01 to 32: Monitor number
w Camera Number
Cam001 to 999: Camera number
C-P0001 to 9999: Camera position number
e Event
HDR01 to 16: Recorder number
Pre000 to 256 (Lighting for 3.0 seconds): Preset position
Note: Pre000 is the home position.
T-A0001 to 0256: Terminal alarm
C-A0001 to 0999: Camera alarm
R-A0001 to 0999: Recorder alarm
S-A0001 to 1024: Serial alarm
V-A0001 to 0999: Video loss
14
36
Lists of Functions and
48
OPERATION (OTHER
w
e
t
y
r Busy
Busy + monitor number (Blinking)
A selected monitor is controlled by a higher-level oper-
ator. (Monitor busy)
Note: You cannot control the selected monitor, camera,
and recorder.
Busy + camera/recorder number (Blinking)
A selected camera or recorder is controlled by a high-
er-level user. (Camera/Recorder busy)
Note: You cannot control the selected camera or
recorder.
t Status
Alarm (Blinking): Alarm is occurring.
Alarm (Lighting): Alarm is acknowledged. (Refer to p.
31.)
Memory + preset position number (Blinking for 3.0 sec-
onds): Preset position is registered.
y Sequence Number
T-Seq01 to 32: Tour sequence number
G-Seq01 to 08: Group sequence number
Note: During sequence pause, "P" is displayed beside
the sequence number.
G-Seq09 to 32: Group preset number
Note: This sign disappears when the camera is con-
trolled.
Invalid (Blinking for 3.0 seconds): You have entered a
wrong value.
Not Avail (Blinking for 3.0 seconds):
• You cannot select a monitor because of lower priori-
ty.
• You have tried to activate a group sequence or
group preset on a monitor not assigned.
Prohibited (Blinking for 3.0 seconds): You have tried an
operation restricted by the level setting.
Alarm Buzzer/Button Buzzer Setting
With the setting activated:
• Alarm buzzer can sound when alarms occur.
• Button buzzer can sound when a button is pressed or
an error message (Invalid, Prohibited, Level1 Fixed,
etc.) is displayed on the LCD.
Refer to the operating instructions of system controller
for settings.