Ir Light Setting; Dome Abnormal Phenomenon Operation; Restore To Factory Default Setup; Ptz Movement Is Not Smooth - IC Realtime PTZ2300SIR User Manual

Ir analog intelligent speed dome
Hide thumbs Also See for PTZ2300SIR:
Table of Contents

Advertisement

ALARM NO: Here is to set alarm input. Alarm input value ranges from 1 to 7. Please use the
left/right button on the keyboard or in the speed dome terminal menu to set.
ACTION: Action on alarm function. It includes NONE/PRESET/AUTO SCAN/TOUR functions.
Please use the left/right button on the keyboard or in the speed dome terminal menu to set.
PARAMETER: it is to set corresponding alarm operation such as scan/preset/tour. Please use the
left/right button to set.
CONTACT:You can set system activation operation once alarm occurred. There are two alarm
signal mode: normal open (N/O) and normal closed (N/C). Please use the left/right button on the
keyboard or in the speed dome terminal menu to set.
RELAY OUT: Here is to set relay alarm mode and reset time. There are several options:
off/1→5S/2→5S/1&2→5S.
1→5S:1 means the first relay output.5S means the relay will reset automatically in five
seconds after alarm occurs.
1&2→5S:1&2 means the first relay and the second relay work at the same time.
RESET DELAY: Here is for you to set alarm reset time. Please use the left/right button on the
keyboard or in the speed dome terminal menu to set: 3 seconds/10 seconds/30 seconds/60
seconds /120seconds. The dome will go back to previous setup after alarm acknowledgement.
SAVE:Move the cursor to SAVE and then click confirm button to save current setup.
BACK: Go back to previous menu.
EXIT: Log out system menu.
3.4.6

IR Light Setting

Move the cursor to highlight IR LIGHT SETTING button and then click confirm button.
IR SENSITIVITY: Here you can enable the IR light sensitivity function.
IR LIGHT CTRL: There are three options: Zoom rate has the higher priority and manual. Please use
the left/right button to set.
NEAR LIGHT: It is the medium and near light brightness. This function is valid in MANUAL mode.
FAR LIGHT: It is the far light brightness. This function is valid in MANUAL mode.
IR LIGHT COMPENSATION: It is the whole compensation level of the IR light. This function is
valid when the zoom rate has the higher priority.
BACK: Go back to the previous menu.
EXIT: Log out the system menu.

3.5 Dome Abnormal Phenomenon Operation

3.5.1 Restore to Factory Default Setup

From main menu-> SYSTEM INFORMATION, move cursor to FACTORY DEFAULT and click confirm
button. Dome will reboot and all the setups restore to factory default setup.

3.5.2 PTZ Movement is not smooth

From menu to SYSTEM INFORMATION, move cursor to RESTART and click confirm button. This
reboot will not modify all activated setup (such as preset, tour and pattern)
IR SENSITIVITY:
IRLIGHT CTRL
NEAR LIGHT
FAR LIGHT
IRLIGHT COMP
BACK
:04
:ZOOM PRI
:50
:50
:03
EXIT
21