DLS/Installer Lead In/Out Group
DLS/Installer Disabled
Digit 5 DLS Connection Options
Option
Programming Section
[401] Option 1 OFF
Option 3 OFF
1
Option 4 OFF
[406] 000
[401] Option 1 ON
Option 3 OFF
2
Option 4 OFF
[406] 008
[401] Option 1 ON
Option 3 ON
3
Option 4 OFF
[406] 008
[401] Option 1 ON
Option 3 OFF
4
Option 4 ON
[406] 008
After entering a valid 5-digit template programming code, the system prompts for the following data in the sequence listed:
1. Central Station Telephone Number
i. Program the required central station phone number. Press [#] to complete your entry.
ii. This phone number is entered into programming section [301][001].
2. Central Station System Account Code (4 or 6-digit code)
i. Program the system account code. All digits must be entered in order to complete your entry.
ii. This account code is entered into programming section [310][000].
3. Partition 1 Account Code (4 digit code)
i. Program the partition 1 account code. All digits must be entered in order to complete your entry.
ii. This account code is entered into programming section [310][001]
4. DLS Access Code (6-digit code)
i. Program the required DLS access code. All 6 digits must be entered in order to complete your entry.
ii. This access code is entered into programming section [403].
5. Entry Delay 1 and Exit Delay
Appendix 3: Template Programming Tables
DLS/Installer Lead In/Out Programming
[308][312] - Bit 1 Installer Lead In - Off
[308][312] - Bit 2 Installer Lead Out - Off
[308][312] - Bit 3 DLS Lead In - Off
[308][312] - Bit 4 DLS Lead Out - Off
[308][312] - Bit 5 SA Lead In - Off
[308][312] - Bit 6 SA Lead Out - Off
DLS Connection/Call Back Setting
Double Call Disabled
Call Back Disabled
User Initiated Call Up Disabled
Number of Rings to Answer On Disabled
Double Call Enabled
Call Back Disabled
User Initiated Call Up Disabled
Number of Rings to Answer On is 8
Double Call Enabled
Call Back Enabled
User Initiated Call Up Disabled
Number of Rings to Answer On is 8
Double Call Enabled
Call Back Disabled
User Initiated Call Up Enabled
Number of Rings to Answer On is 8
- 228 -

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hs2064Hs2032Hs2016-4Hs2016

Table of Contents