Section 6: Programming
OFF: I.D. tone is disabled.
6 – Tone Generated-2100Hz
ON: 2100 Hz I.D. tone.
OFF: 1300 Hz I.D. tone.
7 – 1 Hour DLS Window
ON: When DLS access is enabled ([*][6] option 5 ON), Installer Programming is accessible through DLS or the [*][8] menu
only once during a 1-hour window.
OFF: When DLS access is enabled, Installer Programming is accessible through DLS or the [*][8] menu an unlimited number
of times during a 6-hour window.
8 – FTC Audible Bell
ON: If a Failure to Communicate trouble is generated while the system is armed, the siren activates for the length of bell time-
out or until the system is disarmed.
OFF: If a Failure to Communicate trouble is generated while the alarm system is armed, the siren does not activate but the
keypad buzzer emits trouble beeps until a key is pressed.
[040] User Authentication
This feature enables the installer or master user to select one of two user authentication methods:
01 – User Code or Proximity Tag
The user can access the system by entering a valid code or by presenting a proximity tag.
02 – User Code and Proximity Tag
The user must enter a valid code and present a proximity tag whenever the system prompts for an access code. A proximity
tag is not required to enter [*][8] Installer Programming.
Note: When this option is enabled, the proximity tag and code must belong to the same user.
[041] Access Code Digits
00 – 4-Digit Access Codes
Access codes are 4 digits long.
01 – 6-Digit Access Codes
Access codes are 6 digits long.
Note: This setting is required for EN50131-1 compliant installations using less than 100 access codes.
02 – 8-Digit Access Codes
Access codes are 8 digits long.
Note: This setting is required for EN50131-1 compliant installations using 1000 access codes.
[042] Verified Events
Burglary Verified Counter
This option programs the number of zone activations required to verify an alarm. Valid entries are 000 to 255.
Holdup Verification Counter
This counter determines the number of alarms that must occur within the Holdup verification window before a confirmed Hol-
dup alarm is logged and communicated. Zones with the holdup verification zone attribute enabled contribute to the gen-
eration of a confirmed Holdup alarm in conjunction with this counter and the holdup verification timer.
Burglary Verification Selection
Use this section to select one of the following burglary verification timer modes:
- 109 -