2 – Not Used
3 – Not Used
4 – Transmission Counter in Hours
ON: The alarm system sends a test transmission after the programmed number of hours in the test transmission cycle (Sec-
tion [377], Option 003).
OFF: The alarm system sends a test transmission after the programmed number of days.
5 – Away to Stay Toggle
ON: The alarm system cannot be switched from Away to Stay mode by pressing the [Stay] function key.
OFF: The alarm system can be switched from Away to Stay mode by pressing the [Stay] function key.
6 – 2-Way Audio Disconnect
ON: The system does not disconnect the 2-way audio session if a new event needs to be communicated.
Note: This option applies to new alarm events only. All non-alarm events (except Fire Troubles) are communicated after the
2-Way session has ended.
OFF: The system disconnects the 2-way audio session if a new event occurs.
7 – Trouble Beeps are Silent
ON: When a trouble is detected on the system, trouble beeps are not sounded at the keypad with the exception of Fire
troubles.
OFF: When a trouble is detected on the system, trouble beeps are sounded at the keypad.
Note: This option must be OFF for UL Residential Fire applications.
8 – Keyswitch Arms in Away Mode
ON: Keyswitch arming arms the alarm system in away mode.
OFF: Keyswitches only arm the system in away mode if an entry/exit zone is violated during exit delay.
[023] System Option 11
1 – Ready LED Flashes for Force Arm
ON: If a force arm capable zone is tripped, partition keypads flash the ready LED in the disarmed state instead of illuminating
it steadily. If a non-force arm capable zone is tripped, the ready LED turns off.
OFF: If a force arm capable zone is tripped, the Ready LED is illuminated steadily. If a non-force arm capable zone is tripped,
the Ready LED turns off.
2 – Not Used
3 – Tamper/Fault Detection
ON: The following trouble conditions, when configured to generate audible alarm conditions, will contribute to a burglary veri-
fication sequence when sequential detection is used. When enabled, a bell circuit trouble will also generate an audible
alarm condition using other sirens that assigned to the partition.
TLM trouble
l
Bell circuit trouble
l
Zone fault
l
Module supervisory trouble
l
Alternate Communicator fault
l
Ethernet Trouble
l
OFF: Trouble conditions are displayed and processed as standard operation.
Note: This option applies to the Sequential Detection feature only.
Section 6: Programming