3
Function
Port Number
SMTP Server Timeout

Internet Fax Settings

Function
Basic Mode/Advanced
Mode
Max TX Size
Max Resolution
Coding Mode
POP3 Configuration
Function
POP3 Server Address
Account Name
Password
Auto Reception
Reply Address
Port Number
POP3 Server Timeout
3-26
Description
This function is used to specify the port number for the SMTP
server. Normally, port number 25 is used. (1 to 65535)
This function is used to specify the length of time (30 to 300
seconds) until the connection to the SMTP server times out.
Description
This function is used to specify the default settings for the Basic
and Advanced transmission modes when sending a document
by Internet fax (using the 10-key pad to enter the destination).
("Basic Mode" or "Advanced Mode")
This function is used to specify the maximum document size for
transmission when using the Advanced mode. (Metric models:
"A4", "B4", or "A3"; Inch models: "LT" or "11
This function is used to specify the maximum transmission
resolution when using the Advanced mode. ("Fine" or "Super
Fine")
This function is used to specify the coding method for scan data
that is to be transmitted when using the Advanced mode.
("MH", "MR", or "MMR")
Description
This function is used to specify the IP address or host name of
the POP3 server. (Up to 64 characters)
This function is used to specify the account name used to log
in to the POP3 server. (Up to 64 characters)
This function is used to specify the password associated with
the account name used to log in to the POP3 server. (Up to 32
characters)
This function is used to specify the time interval (between 1 and
60 minutes) for checking e-mail when the Auto Reception
function is enabled.
This function is used to specify the return e-mail address for
error messages. If an error occurs, an error message will be
sent to the e-mail address specified here. Normally, the reply
address is set to the e-mail address of the administrator. (Up to
64 characters)
This function is used to specify the port number for the POP3
server. Normally, port number 110 is used. (1 to 65535)
This function is used to specify the length of time (30 to 300
seconds) until the connection to the POP3 server times out.