Fault Indications On The Lcd Display - Meyra SPRINT GT 2.593 Operating Manual

Table of Contents

Advertisement

SERVICE
FAULT INDICATIONS ON THE
LCD DISPLAY
An error code appears or the signalling
bar flashes on the LCD display if there is
a malfunction.
The error codes help the specialist work-
shop to quickly identify the cause of the
malfunction.
The electronics performs a self-test after
the control box has been switched on.
The signalling bar blinks until this self-test
has been completed.
Do not move the joystick out of the zero
position during the self-test. – If you do,
switch off the wheelchair and then switch
on again and wait until the signalling bar
stops blinking.
Indication and effect
E 54, E 55
Warning E 54,
the wheelchair standstill E 55
Cause
Low battery voltage due to fully dis-
charged batteries.
Remedy
Recharge batteries immediately.
Recharge batteries!
Contact your authorised dealer in the
event of other error indications.
30
TECHNICAL DATA
All data in the following tables refer to
the standard model version.
Dimensional tolerance is ± 1.5 cm.
Overload limiting
40A min. for 15 sec. min.
Blade-type fuses
60A main fuse (6 km/h)
60A main fuse (10 km/h)
20A charging fuse
2A
power electronics control
7,5A electrical adjustments
5A
lighting
5A
steering
Filament bulbs
Headlights:
Ball lamp
24V/3W E10
Back light:
Festoon bulb
24V/C5W S8,5
Front indicator:
Ball lamp
24V/10W BA15s
Rear indicator:
Ball lamp
24V/21W BA15s