PR PRecon 5223 Manual page 31

Programmable f/i - f/f converter
Table of Contents

Advertisement

Available languages

Available languages

Relay output:
Frequency max. .......................................... 20 Hz
V max. ......................................................... 250 VRMS
I max. ........................................................... 2 A / AC
Max. AC power .......................................... 500 VA
Max. AC power Ex version 5223B ............. 100 VA
Max. load at 24 VDC .................................. 1 A.
EEx / I.s. approval -5223B:
KEMA 04ATEX1001 .....................................
Applicable in zone ...................................... 0, 1, 2, 20, 21 or 22
Ex / I.s. data:
Terminal 31, 33
U m .............................................................. : 250 V
Terminal 42, 43 and 52, 53
U o ............................................................... : 10.6 VDC
I o ................................................................. : 13.8 mA
Po ............................................................... : 38 mW
L o ............................................................... : 160 mH
C o ............................................................... : 1.9 µF
GOsT R approval:
VNIIM & VNIIFTRI, Cert. no. ........................ See www.prelectronics.com
Observed authority requirements:
EMC 2004/108/EC ..................................... EN 61326-1
LVD 2006/95/EC ......................................... EN 61010-1
PELV/SELV .................................................. IEC 364-4-41 and EN 60742
ATEX 94/9/EC ............................................. EN 50014, EN 50020 and
Of span = Of the presently selected range
II (1) GD
[EEx ia] IIC
standard:
EN 50284
29