REMOTE CONTROL

5. REMOTE CONTROLLER OPERATION

5.1. OPTIONAL LIQUID CRYSTAL REMOTE CONTROL PC-P1HE

Fan Speed Indicator
It indicates the fan speed you have selected:
High / Medium / Low
-
Total Ventilator Indicator
It indicates if Total Ventilator have been selected.
A/C only air conditioning
-
VENTI only ventilation
-
A/C + VENTI when both have been selected.
-
Operation Mode Indicator
Indicates the operation mode selected:
Fan, Cool, Heat, Dry, Auto (Cool/Heat)
Run Indicator (Red Lamp)
RUN/STOP Switch
MODE (Operation Mode Selection) Switch
FAN SPEED (Fan Speed Selection) Switch
Up & Down Panel Operation Switch
(Not Available)
-
VENTI (Ventilator Operation) Switch
LOUVER (Swing Louver Operation) Switch
TIME (Time Setting) Switch
Increases and decreases the Set Time for timer operation
-
ON/OFF TIMER Switch
-
Used to activate or deactivate the timer operation
CHECK Switch
RESET (Filter Reset Switch)
After cleaning the air filter, press the "RESET" button.
-
The filter indication
will disappear and the next filter cleaning
-
time is reset. It also stops the Alarm indication procedure.
TEMP (Temperature Setting) Switch
T.RUN (Test Run Indication)
Check (Check Indication)
These Tests appears when "TEST RUN" or "CHECK" is being
-
performed
ABNML (Alarm) Indicator
"FILTER" Indicator
SET TEMP (Set Temperature) Indicator
ON/OFF Timer (Timer Operation Indicator)
Alarm Code Indicator
"NO FUNCTION" Indicator
CENTRAL (Central Control Indicator)
Indicates that central station or CS-Net is being performed
-
Swing Louver Indicator
"DEFROST" Indicator
When opening the cover, pull the
cover toward the arrow direction
NOTE:
Do not use this system as constant temperature and
-
constant humidity control equipment.
In the case that the LOW fan speed is selected and outdoor
-
temperature is higher than 21°C, excessive load is given to
the compressor at heating operation. Therefore, set the fan
speed at HIGH or MEDIUM, since safety devices may be
activated.
When the system is started after a shutdown longer than
-
approximately 3 months, it is recommended to check the
system by your service contractor.
Turn OFF the main switch when the system is stopped for a
-
long period of time.
If the main switch is not turned OFF, electricity is
-
consumed, because the oil heater is always energized
during compressor stopping.