5. REMOTE CONTROLLER OPERATION

5.1. OPTIONAL LIQUID CRYSTAL REMOTE CONTROL (PC-P2HTE)
Model:
Fan speed indicator
It indicates the fan speed you have selected:
-
High/Medium/low
Indicador de vantilador Total
It indicates if Total ventilator has been selected.
-
A/C
only air conditioning
-
VENTI
only ventilation
-
A/C + VENTI
if both are selected
Operation Mode Indicator
Indicates the operation mode selected: Fan, Cool,
Heat, Dry, Auto (Cool/Heat)
Run indicator (Red Lamp)
RUN/STOP switch
MODE (Operation Mode Selection) Switch
FAN SPEED (Fan Speed Selection) Switch
Up & Down Panel Operation Switch
VENTI(Ventilator Operation) Switch
LOUVER (Swing Louver Operation) Switch
SELECT (time setting) switch
Increase and decreases the set Time for timer
operation
ON / OFF Timer (Timer Operation) Indicator
Used to activate or deactivate the timer operation
PC-P2HTE
REMOTE CONTROLLER OPERATION
OK Switch
RESET (Filter Reset) Switch
After cleaning the air filter, press the "RESET" button.
The FILTER indication will disappear and the next
filter cleaning time will be set.
It also stops the run procedure.
TEMP (Temperature Setting) Switch
T.RUN (Test Run Indication)
Check (Check Indication)
These Tests appears when "TEST RUN" or "CHECK"
is being performed
ABNML (Alarm) Indicator
"FILTER" Indicator
SET TEMP (Setting Temperature) Indicator
1234S indicator (setting schedule number)
Mon Tue ... Sun (Day of the week indicator)
Indicates that central station or CSNET WEB is being
performed
Swing Louver Indicator
"DEFROST" is indicated
SERVICE mode indicator. (indicates the change
to special operations)
Time indicator.
Time indicator. (indicates the programmed time).
When opening the cover, pull the cover
toward the arrow direction
NOTE:
− In the case that the LOW fan speed is selected and
outdoor temperature is higher than 21°C, excessive
load is given to the compressor at heating operation.
Therefore, set the fan speed at HIGH or MEDIUM,
since safety devices may be activated.
− When the system is started after a shutdown longer
than approximately 3 months, it is recommended that
the system be checked by your service contractor.
− Turn OFF the main switch when the system is stopped
for a long period of time. Otherwise the system
consumes electricity as the oil heater remains active
even though the compressor is stopped.