Data required
Display name: Program name to be displayed on the phone.
Value specifications:
It must be unique on the phone.
It cannot contain the '^' character.
It cannot not be empty.
Its length cannot not exceed 20 characters.
Application name: Used internally to identify the XML application running on the phone.
Value specifications:
It must be unique on the phone.
It cannot contain non-alphanumeric characters, spaces for instance.
The first character must be a letter.
It must not be empty.
Its length must not exceed 20 characters.
Protocol: Communication protocol for the data exchange with the server.
Value range: „HTTP", „HTTPS".
Default: „HTTPS".
Server address: IP address or domain/host name of the server that provides the applica-
tion or the XML document.
Server port number: Number of the port that the server uses to provide the application or
XML document.
Program name: Relative path to the servlet or to the first XML page of the application on
the server.
XML trace enabled: Enables or Disables the debugging of the XML application.
Value range: "Yes", "No".
Default: „No".
Debug program name: The relative path to a special servlet that receives the debug in-
formation.