Removing And Replacing The Main Rackswitch Chassis Unit; Configuring Vital Product Data After A Switch Replacement - IBM RackSwitch G8264CS Installation Manual

Hide thumbs Also See for RackSwitch G8264CS:
Table of Contents

Advertisement

required information that is necessary to return a component. After you remove the
component, securely pack the component for shipping.
For instructions to replace the air duct, see "Installing the 1U air duct option" on
page 28.

Removing and replacing the main RackSwitch chassis unit

When replacing a RackSwitch chassis unit, all internal component must also be
removed from the chassis and replaced in the new chassis. The RackSwitch
operates with one or two active power supplies, up to four fan modules, and an
optional air duct unit.
When you remove a RackSwitch unit from the rack, record the product MTM
number and serial number to use for the replacement switch, see "Before installing
the RackSwitch" on page 15 to locate the product information labels on the switch
chassis or "Configuring Vital Product Data after a switch replacement" to use an
interface to display the product information for the RackSwitch.
Before you replace the RackSwitch chassis, you must remove and replace the
separate components. For more information about removing and replacing
RackSwitch components, see the following sections:
v "Removing and replacing a power supply module" on page 42
v "Removing and replacing a fan module" on page 44
To return the chassis to customer service for replacement, see Appendix A, "Getting
help and technical assistance," on page 65, to help you gather all the required
information that is necessary to return a component. After you remove the chassis
unit, securely pack the RackSwitch unit for shipping.
To replace the RackSwitch chassis in the rack, see the following procedures and
perform them in the order in which they are listed.
v "Replacing a power supply module" on page 43
v "Replacing a fan module" on page 45
v Chapter 2, "Installing the RackSwitch and options," on page 15

Configuring Vital Product Data after a switch replacement

After you replace a RackSwitch, you must update the new switch with the VPD of
the RackSwitch being removed to avoid losing the licensed electronic entitlement
data of the RackSwitch. The VPD includes the model and serial number of the
switch. For more information on locating the VPD, see "Before installing the
RackSwitch" on page 15.
To update the VPD on a new switch, complete the following steps.
1. Log in to the switch and in the CLI mode, type
2. At the Password prompt, enter the switch password, and press Enter. The
3. In the main menu, enter the MTM number for the replacement switch. For
46
IBM System Networking RackSwitch G8264CS: Installation Guide
RS G8264>ibmnos
default password is admin.
example: