CO Alarm Memory:
Repeater Function
Dimensions
: A unit will indicate if it has been in alarm previously by flashing the red light
for 2 seconds every 40 seconds (2 flashes for 50 ppm CO, 4 flashes for
100 ppm CO and 8 flashes, for 300 ppm CO). When the Test/Hush button
is pressed, the red light flashes (as per Table B on page 8) to indicate the
previous CO alarm level detected. The memory is cleared by holding down
the Test/Hush button until the red light stops flashing.
: To disable the Repeater function press and hold the Test/Hush button
until the alarm sounds and the red RadioLINK light turns on. Immediately
(while the red RadioLINK light is still on), press and hold the House Code
switch with a small screwdriver, until the red indicator light gives 3 slow
flashes. Immediately release the House Code switch and Test/Hush button.
To re-activate the Repeater function just follow the instructions above for
disabling. The RadioLINK light will flash 15 or 16 times and stop to show
the Repeater function is now activated.
: 126 x 150 x 42 mm.
Weight: 330g.