Testing with CO
Initialisation Time
Operating Temperature
Humidity Range
Radio Frequency
RF Power
Range
Entering House Code Mode: Pressing and holding the House Code switch until the green light turns
red, then releasing puts the Alarm into House Code mode.
House Code Mode: The Alarm transmits and receives specific codes. The green light will flash red every
5 or 10 seconds (depending on number of units coded - up to 12 units, the flashes are every 5 seconds,
above 12 units the flashes are every 10 seconds) to indicate the number of House Coded units in the
system.
Duration of House Code Mode: Exits mode automatically after 30 minutes (Alternatively manually
exit by pressing the House Code button; this sends a RadioLINK "exit House Code" signal to all other
RadioLINK units.
: The red alarm light flashes as soon as the Alarm detects CO, so there is no
need to retain CO in the Alarm for several minutes until it sounds.
: 70 seconds. On power up red and amber lights flash momentarily to show
they are operational.
: -10°C to 40°C
: 15% to 95% R.H. (non-condensing)
: 868 MHz band
: +5dBm
: 100 meters (minimum) in free space (without use of the "Repeater" function)