Ei Electronics Ei262 Leaflet page 19

Hide thumbs Also See for Ei262:
Table of Contents

Advertisement

with 3 units in the system should give 3 short flashes every 5 seconds, 4 units should give 4 short flashes
and so on, up to 12 units. It may take up to 30 minutes for all the units in the system to be House Coded
correctly. Check that the other RadioLINK units are House Coded as per their instructions. If at the end
of this period certain units do not show the correct number of flashes, repeat the process (from point 1
above) once more and if this fails see - Section 14 Troubleshooting on page 36.
5. The units will automatically exit the House Code learn mode after 30 minutes however we recommend
that you manually exit the House Code mode by pressing and holding the House Code switch on
the Ei262 until the RadioLINK Indicator light turns red, and then release. The RadioLINK Indicator light
should stop flashing and an 'exit House Code' signal will be sent to all other units.
Check that the RadioLINK Indicator lights on all other units have stopped flashing. (If some units are
still flashing it may indicate a problem with the radio communication from this unit to the other units, or
these units may have to be taken out of House Code mode manually, see their instruction manuals.
Repeat the process once more and if this fails see - Section 14 Troubleshooting on page 36. Manually
exiting the House Code mode reduces the risk of accidentally House Coding your RadioLINK units with
nearby systems).
6. Check the communications by pressing the Test/Hush button on the Ei262 for up to 10 seconds. The
alarm will sound and then pause briefly while the RadioLINK signal is transmitted. The green power light
will turn red for this duration (approx 3.5 seconds). All other alarms should sound (this may take up to 20
seconds as the signal may need to be relayed through "repeaters" - see next page). Release the Test/
Hush button. The local alarm will cease and you should then be able to hear the other alarms sounding
in the distance and then stopping. Note: The local alarm may sound again depending on the number of
repeaters in the system as it acknowledges the repeated signals. Similarly check each RadioLINK unit in
the same way (if any of the alarms do not sound, see - Section 14 Troubleshooting.