Lighting The Appliance; Checking For Clearance Of Combustion Products - Flavel Renoir FRECR0MN Installation And Maintenance Instructions Manual

Radiant convector gas fire
Table of Contents

Advertisement

g)
Refit the glass panel, ensuring the retaining disc is rotated to
secure panel.
IMPORTANT: Ensure decorative front casting is fitted prior to light
ing appliance.
3.2

Lighting the Appliance

a)
Light the pilot by depressing the control knob at the "off" position and
turn anti-clockwise (with the control depressed) to the second position
marked *.
b)
When the pilot lights, (pilot can be seen through the right hand side
window, between the fuelbed base and coals) hold the control knob
down for 10 seconds.
c)
If the pilot fails to light, repeat the ignition sequence and hold in the
control knob for slightly longer.
d)
When the pilot has lit, , then release the control knob from the
depressed position, depress slightly again and turn the control anti-
clockwise to the high position and check for clear once of combustion
products as detailed below.
3.3

Checking for Clearance of Combustion Products

a)
Close all doors and windows in the room.
b)
Light the fire and turn to the maximum position.
After 5 minutes hold the smoke match as shown in Fig. 11. Whilst
holding the smoke match in the correct position, approximately 25mm
below the lower edge of the draught diverter.
Ensure that most of the smoke is drawn into the flue aperture. If in
doubt repeat the exercise after a further 5/10 minutes.
Note:-
It is recommended that the smoke match is fitted into an approved
smoke match holder, when checking for clearance of combustion
products.