Multiple Galactic (Dmx Control); Fixture Linking; Data Cabling - SHOWTEC gatactic RGB-600 value series User Manual

Hide thumbs Also See for gatactic RGB-600 value series:
Table of Contents

Advertisement

Multiple Galactic
1.
Fasten the effect light onto firm trussing
2. Always use a safety cable (ordercode 70140 / 70141).
3.
Use a 3-p XLR cable to connect the Galactic lasers.
4.
Link the units as shown in (figure 4), Connect a DMX signal cable from the first unit's DMX "out" socket
to the second unit's "in" socket. Repeat this process to link the second, third, and fourth units.
5. Supply electric power: Plug the end of the mains power cord into proper electric power supply
sockets. Do so for all units and the controller.
Note : Link all DMX cables and set dip switches before connecting electric power
6.
Do not supply power before the whole system is set up and connected properly. Design your show
according to your DMX controller functions. See page 13 for more about DMX programming.

Fixture Linking

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to
run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined
number of channels required by all the fixtures on a serial data link determines the number of fixtures the
data link can support.
Important:
Fixtures on a serial data link must be daisy chained in one single line. To comply with the
EIA-485 standard no more than 30 devices should be connected on one data link.
Connecting more than 30 fixtures on one serial data link without the use of a DMX optically
isolated splitter may result in deterioration of the digital DMX signal.
Maximum recommended DMX data link distance: 100 meters
Maximum recommended number of Galactics on a DMX data link: 30 fixtures

Data Cabling

To link fixtures together you must obtain data cables. You can purchase DAP Audio certified DMX cables
directly from a dealer/distributor or construct your own cable. If you choose to create your own cable
please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic
interference.
DAP Audio Certified DMX Data Cables
DAP Audio Basic microphone cable for allround use.
Ordercode FL01150 (1,5m.), FL013 (3m.), FL016 (6m.), FL0110 (10m.), FL0115 (15m.), FL0120 (20m.).
DAP Audio cable
Neutrik®. Ordercode FL71150 (1,5m.), FL713 (3m.), FL716 (6m.), FL7110 (10m.).
(DMX
Control)
Multiple Galactics Pro Set Up
for the demanding user with exceptional audio-qualities and connector made by
Leave at least 1 meter on all sides for air circulation.
bal. XLR/M 3 p. > XLR/F 3 p.
11
Max. 30 Galactics
Fig. 4

Advertisement

Table of Contents
loading

Table of Contents