2
BASIC OPERATION

■ Stun function

When the specified ID, set as a kill ID, is received, the stun
function is activated.
When the kill ID is received, the transceiver switches to the
password required condition. Entering of the password (p. 8)
is necessary to operate the transceiver again in this case.

■ Priority A channel selection

When one of the following operations is performed, the trans-
ceiver selects the Priority A channel automatically.
• Turning the power ON
The Priority A channel is selected each time the transceiver
power is turned ON.
• Status call
The Priority A channel is selected when transmitting a sta-
tus call. (BIIS operation only)
• Off hook.
The Priority A channel is selected when the microhone is
took off from its hanger.
13

■ Automatic Key Lock function

When [Lock] is assigned to any key and the Automatic Key
Lock timer is pre-programmed* by your dealer, the key lock
function can be automatically turned ON after the specified
time period has passed without operation during standby
condition.
While the lock function is ON, hold down [Lock] for 1 second
to turn the function OFF.
*When "0" is programmed, this function is not available.