LIGHTER FLUID, SOLVENT TYPE CLEANERS, OIL-BASE PAINTS, GASOLINE, ALCOHOL OR
AEROSOL SPRAYS. EXPLOSIVE DUSTS INCLUDE BUT ARE NOT LIMITED TO;
COAL, MAGNESIUM, GRAIN OR GUN POWDER. TO REDUCE THE RISK OF HEALTH
HAZARDS FROM VAPORS OR DUST, DO NOT VACUUM TOXIC MATERIALS.
CAUTION:
NEVER operate the vacuum cleaner without all of the filters
installed. This includes the HEPA filter, pre-filter and collection bag. Motor
damage, lose of operating efficiency and recirculation of hazardous material
into the work area will take place if not installed.
1. Verify that the power cord is disconnected from the power socket. (fig. 1)
2. In order to prepare your vacuum cleaner for dry vacuuming, verify that
the HEPA filter is securely mounted. With power head removed and in the
upside down position, make sure the filter is pushed in until it stops
against the power head and the rubber flat washer and retainer are
installed. (fig. 2 & 3)
3. Slide the pre-filter onto the assembled HEPA filter. Tighten the band
clamp on the pre-filter with a screwdriver to ensure. (fig. 4 & 5) (Your wet
7
and dry vacuum cleaner comes with the HEPA filter and pre-filter
pre-installed, if not, see page 9 for installation instructions.)
4. Optional, for improved dust collecting, fit collection bag flange onto the
inlet stub, taking care not to damage the bag. (fig. 6)
5. Place the power head back on the container, and secure it in place using
the latches. (fig. 7)
OPERATING INSTRUCTIONS: DRY VACUUMING
1. Insert the locking end of the hose into the vacuum port and lock in
place.Push the required attachment onto the free end of the hose or
extension. (fig. 8)
2. Plug in the power cord into the power socket. (fig. 9)
3. Turn the motor on by turning the switch to the 'I' ON position. (fig. 10)
4. Once you have completed vacuuming, flip the switch to the 'O' OFF
position and unplug the power cord from the power socket.
I = ON
II = ON/OFF with a power tool
Middle position = OFF
WARNING:
IF FILTERS ARE CONTAMINATED OR HAVE BEEN USED, THEY MUST
BE DISPOSED OF PROPERLY, PRIOR TO PERFORMING WET VACUUMING OPERATIONS.
DO NOT USE THE HEPA FILTER FOR LIQUID VACUUMING.
Hazardous materials must be disposed of properly. NEVER throw contaminated debris
in your usual trash receptacle. Place debris in a approved poly bag or container
marked with HAZARDOUS MATERIAL warning and dispose in accordance with your
local Hazardous Waste Regulations.
Position I switches the vacuum cleaner on
Position II switches the vacuum cleaner to stand by so that it switches on and off
automatically with a power tool that is plugged into the on-board socket.
to allow the suction tube to be emptied.
So that the switch is in the mid position.