Technical Data - Grundfos Sololift2 C-3 Installation And Operating Instructions Manual

Automatic lifting station suitable for pumping grey wastewater
Table of Contents

Advertisement

8. Technical data

Supply voltage
1 x 220-240 V - 10 %/+ 6 %, 50 Hz.
Power consumption
640 W.
Power factor
Cos φ 0.66 / 0.90.
Speed
-1
2800 min
.
Rated current
3.1 A.
Insulation class
F.
Noise level
< 70 dB(A) to 12050-2.
Flow rate
Max. 204 l/min.
System pressure
Max. pump head: 8.0 m.
Max system head: 6.0 m.
The system pressure should not
exceed 6 m head to guarantee a
Note
sufficient drain of the connected
sanitary appliances.
Supply cable
2
1.2 m, 0.75 mm
(H05VV-F-3G).
Net weight
6.6 kg.
Start and stop levels
Start level 1: 65 mm above floor level.
Start level 2: 115 mm above floor level.
Stop level: 35 mm above floor level.
Liquid temperature
75 °C continuously (90 °C for 30 min.).
Ambient temperature
+5 °C to +35 °C.
Duty
S3 - 50 % - 1 min. (30 sec. on; 30 sec. off).
Marking
Approvals
9