Bosch AutoDome Junior HD VJR Series Operation Manual page 45

Hide thumbs Also See for AutoDome Junior HD VJR Series:
Table of Contents

Advertisement

AutoDome Junior HD Series
Max. Input Voltage
Impedance
Sample Rate
Shield
Internal gain level adjustment is available
Wire Specifications
Wire Type
Distance
Gage
Shield
Center conductor Stranded bare copper
Bosch Security Systems, Inc.
5.5 Vpp
9 K Ω
G.711: 8 bits @ 8 KHzL16: 16 bits @
16 kHz PCM
Bare copper braid: 95% coverage
Coax
(recommended)
3
10 m (33 ft)
22 AWG
Bare copper braid: 95% coverage
Operation Manual
Audio, Alarms and Relay Connections | en
2014.11 | 6.1 | F.01U.275.803
45