B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 18 of 60)
ADDR
REGISTER NAME
40AB
DNP Unsolicited Responses Maximum Retries
40AC
DNP Unsolicited Responses Destination Address
40AD
Ethernet Operation Mode
40AE
DNP Current Scale Factor
40AF
DNP Voltage Scale Factor
40B0
DNP Power Scale Factor
40B1
DNP Energy Scale Factor
40B2
DNP Power Scale Factor
40B3
DNP Other Scale Factor
B
40B4
DNP Current Default Deadband
40B6
DNP Voltage Default Deadband
40B8
DNP Power Default Deadband
40BA
DNP Energy Default Deadband
40BC
DNP Power Factor Default Deadband
40BE
DNP Other Default Deadband
40C0
DNP IIN Time Synchronization Bit Period
40C1
DNP Message Fragment Size
40C2
DNP Client Address 3
40C4
DNP Client Address 4
40C6
DNP Client Address 5
40C8
DNP Number of Paired Binary Output Control
Points
40C9
DNP TCP Connection Timeout
40CA
DNP Communications Reserved (22 items)
40E0
TCP Port Number for the IEC 60870-5-104
Protocol
40E1
IEC 60870-5-104 Protocol Function
40E2
IEC 60870-5-104 Protocol Common Address of
ASDU
40E3
IEC 60870-5-104 Protocol Cyclic Data
Transmission Period
40E4
IEC 60870-5-104 Current Default Threshold
40E6
IEC 60870-5-104 Voltage Default Threshold
40E8
IEC 60870-5-104 Power Default Threshold
40EA
IEC 60870-5-104 Energy Default Threshold
40EC
IEC 60870-5-104 Power Factor Default Threshold
40EE
IEC 60870-5-104 Other Default Threshold
40F0
IEC 60870-5-104 Client Address (5 items)
4104
IEC 60870-5-104 Redundancy Port Enabled/
Disabled
4105
Port 2 IP Address
4107
Port 2 IP Subnet Mask
4109
Port 2 Gateway IP Address
410B
PRT2 Ethernet Operation Mode
410C
PRT2 Redundancy Enabled
410D
Port 3 IP Address
410F
Port 3 IP Subnet Mask
4111
Port 3 Gateway IP Address
4113
Port 3 Ethernet Operation Mode
B-26
RANGE
1 to 255
0 to 65519
0 to 1
0 to 8
0 to 8
0 to 8
0 to 8
0 to 8
0 to 8
0 to 100000000
0 to 100000000
0 to 100000000
0 to 100000000
0 to 100000000
0 to 100000000
1 to 10080
30 to 2048
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 32
10 to 7200
0 to 1
0 to 65535
0 to 1
0 to 65535
1 to 65535
0 to 100000000
0 to 100000000
0 to 100000000
0 to 100000000
0 to1
0 to 100000000
0 to 4294967295
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
B30 Bus Differential System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F001
---
1
F001
---
1
F192
---
1
F194
---
1
F194
---
1
F194
---
1
F194
---
1
F194
---
1
F194
---
1
F003
---
1
F003
---
1
F003
---
1
F003
--
1
F003
---
1
F003
min
1
F001
---
1
F001
---
1
F003
---
1
F003
---
1
F003
---
1
F001
s
1
F001
---
1
F001
---
1
F001
---
1
F102
---
1
F001
s
1
F001
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
0.01
F001
---
1
F003
---
1
F003
---
1
F126
---
1
F003
---
1
F003
---
1
F003
---
1
F192
---
1
F126
---
1
F003
---
1
F003
---
1
F003
---
1
F192
DEFAULT
10
1
1 (Full-
Duplex)
2 (1)
2 (1)
2 (1)
2 (1)
2 (1)
2 (1)
30000
30000
30000
30000
30000
30000
1440
240
0
0
0
0
120
0
2404
0 (Disabled)
0
60
30000
30000
30000
30000
100
30000
0
0 (No)
56554706
4294966272
56554497
1 (Full-
Duplex)
0 (No)
56554706
4294966272
56554497
1 (Full-
Duplex)