Table B–10: MODBUS MEMORY MAP (Sheet 13 of 60)
ADDR
REGISTER NAME
3879
Field Unit 2 Process Card Port
387A
Field Unit3 Process Card Port
387B
Field Unit 4 Process Card Port
387C
Field Unit 5 Process Card Port
387D
Field Unit 6 Process Card Port
387E
Field Unit 7 Process Card Port
387F
Field Unit 8 Process Card Port
Field Unit CT VT Settings (Read/Write Setting) (6 modules)
3890
Remote Phase CT x Origin 1
3891
Remote Phase CT x Origin 2
3892
Remote Ground CT x Origin 1
3893
Remote Ground CT x Origin 2
3894
AC Bank Redundancy Type
3895
Remote Phase CT 1 Primary
3896
Remote Phase CT 1 Secondary
3897
Remote Ground CT 1 Primary
3898
Remote Ground CT 1 Secondary
3899
Remote Phase VT 1 Connection
389A
Remote Phase VT 1 Secondary
389B
Remote Phase VT 1 Ratio
389D
Remote Auxiliary VT 1 Connection
389E
Remote Auxiliary VT 1 Secondary
389F
Remote Auxiliary VT 1 Ratio
38A1
...Repeated for module number 2
38B2
...Repeated for module number 3
38C3
...Repeated for module number 4
38D4
...Repeated for module number 5
38E5
...Repeated for module number 6
Field Unit Contact Inputs (Read/Write Setting) (40 modules)
3900
Field Contact Input 1 ID
3906
Field Contact Input 1 Origin
3907
Field Contact Input 1 Input
3908
Field Contact Input 1 Failsafe Value
3909
Field Contact Input 1 Debounce Time
390A
Field Contact Input 1 Events
390B
...Repeated for Field Contact Input 2
3916
...Repeated for Field Contact Input 3
3921
...Repeated for Field Contact Input 4
392C
...Repeated for Field Contact Input 5
3937
...Repeated for Field Contact Input 6
3942
...Repeated for Field Contact Input 7
394D
...Repeated for Field Contact Input 8
3958
...Repeated for Field Contact Input 9
3963
...Repeated for Field Contact Input 10
396E
...Repeated for Field Contact Input 11
3979
...Repeated for Field Contact Input 12
3984
...Repeated for Field Contact Input 13
398F
...Repeated for Field Contact Input 14
GE Multilin
RANGE
0 to 7
0 to 7
0 to 7
0 to 7
0 to 7
0 to 7
0 to 7
0 to 16
0 to 16
0 to 16
0 to 16
0 to 2
1 to 65000
0 to 1
1 to 65000
0 to 1
0 to 1
25 to 240
1 to 24000
0 to 6
25 to 240
1 to 24000
---
0 to 8
1 to 18
0 to 1
0 to 16
0 to 1
B30 Bus Differential System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F244
---
1
F244
---
1
F244
---
1
F244
---
1
F244
---
1
F244
---
1
F244
---
1
F247
---
1
F247
---
1
F248
---
1
F248
---
1
F261
---
1
F001
---
1
F123
---
1
F001
---
1
F123
---
1
F100
---
0.1
F001
---
1
F060
---
1
F166
---
0.1
F001
---
1
F060
---
1
F205
---
1
F256
---
1
F001
---
1
F108
ms
0.5
F001
---
1
F102
DEFAULT
4 (H2a)
2 (H3a)
0 (H4a)
7 (H1b)
5 (H2b)
3 (H3b)
1 (H4b)
0 (None)
0 (None)
B
0 (None)
0 (None)
1
(Dependabilit
y Biased)
1
0 (1 A)
1
0 (1 A)
0 (Wye)
664
1
1 (Vag)
664
1
"FCI 1"
0 (None)
1
0 (Off)
20
1 (Enabled)
B-21