GE B30 UR Series Instruction Manual page 459

Bus differential system
Hide thumbs Also See for B30 UR Series:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 39 of 60)
ADDR
REGISTER NAME
A315
Digital Counter 1 Reset
A317
Digital Counter 1 Freeze/Reset
A319
Digital Counter 1 Freeze/Count
A31B
Digital Counter 1 Set To Preset
A31D
Reserved (11 items)
A328
...Repeated for Digital Counter 2
A350
...Repeated for Digital Counter 3
A378
...Repeated for Digital Counter 4
A3A0
...Repeated for Digital Counter 5
A3C8
...Repeated for Digital Counter 6
A3F0
...Repeated for Digital Counter 7
A418
...Repeated for Digital Counter 8
FlexCurves C and D (Read/Write Setting)
A600
FlexCurve C (120 items)
A680
FlexCurve D (120 items)
Non Volatile Latches (Read/Write Setting) (16 modules)
A700
Non-Volatile Latch 1 Function
A701
Non-Volatile Latch 1 Type
A702
Non-Volatile Latch 1 Set
A704
Non-Volatile Latch 1 Reset
A706
Non-Volatile Latch 1 Target
A707
Non-Volatile Latch 1 Events
A708
Reserved (4 items)
A70C
...Repeated for Non-Volatile Latch 2
A718
...Repeated for Non-Volatile Latch 3
A724
...Repeated for Non-Volatile Latch 4
A730
...Repeated for Non-Volatile Latch 5
A73C
...Repeated for Non-Volatile Latch 6
A748
...Repeated for Non-Volatile Latch 7
A754
...Repeated for Non-Volatile Latch 8
A760
...Repeated for Non-Volatile Latch 9
A76C
...Repeated for Non-Volatile Latch 10
A778
...Repeated for Non-Volatile Latch 11
A784
...Repeated for Non-Volatile Latch 12
A790
...Repeated for Non-Volatile Latch 13
A79C
...Repeated for Non-Volatile Latch 14
A7A8
...Repeated for Non-Volatile Latch 15
A7B4
...Repeated for Non-Volatile Latch 16
IEC 61850 Received Analog Settings (Read/Write Setting) (32 modules)
AA00
IEC 61850 GOOSE Analog 1 Default Value
AA02
IEC 61850 GOOSE Analog Input 1 Mode
AA03
IEC 61850 GOOSE Analog Input 1 Units
AA05
IEC 61850 GOOSE Analog Input 1 Per-Unit Base
AA07
...Repeated for IEC 61850 GOOSE Analog Input 2
AA0E
...Repeated for IEC 61850 GOOSE Analog Input 3
AA15
...Repeated for IEC 61850 GOOSE Analog Input 4
AA1C
...Repeated for IEC 61850 GOOSE Analog Input 5
AA23
...Repeated for IEC 61850 GOOSE Analog Input 6
GE Multilin
RANGE
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
---
0 to 65535
0 to 65535
0 to 1
0 to 1
0 to 4294967295
0 to 4294967295
0 to 2
0 to 1
---
–1000000 to 1000000
0 to 1
---
0 to 999999999.999
B30 Bus Differential System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
---
F001
ms
1
F011
ms
1
F011
---
1
F102
---
1
F519
---
1
F300
---
1
F300
---
1
F109
---
1
F102
---
---
F001
---
0.001
F060
---
1
F491
---
---
F207
---
0.001
F060
DEFAULT
0
0
0
0
0
B
0
0
0 (Disabled)
0 (Reset
Dominant)
0
0
0 (Self-reset)
0 (Disabled)
0
1000
0 (Default
Value)
(none)
1
B-47

Advertisement

Table of Contents