Dockside setup
Initiating the required dockside setup is done from within the
Commissioning dialog. Completed procedures are labelled with a
tick. When the autopilot computer is delivered from the factory AND
ANY TIME AFTER AN AUTOPILOT RESET HAS BEEN PERFORMED, you
will have to run a complete setup again.
All steps in all commissioning procedures are clearly described on-
screen, and you are guided step by step through the process.
1.
Press the STBY key to ensure that the autopilot is in standby
mode.
2.
Select the Commissioning option and clear the displayed
dialog by pressing the STDBY key.
3.
Select your boat type.
- The boat type setting is used by the system to select
appropriate preset steering parameters. It also affects
available autopilot features.
Ú Note:
This option is not available for NAC-1 computers.
4.
Perform the rudder calibration.
- Used if you have a rudder feedback unit installed. This
calibration is used to ensure that the physical rudder
Software Setup