Related Commands - HP HSR6600 Troubleshooting Manual

Hide thumbs Also See for HSR6600:
Table of Contents

Advertisement

If the command output contains the message, go to 3.
3.
Locate the pci device in subslot x message in the command output and copy the text in the square
brackets (<>) on the left of the message. Then execute the display hardware internal pci config x
slot y command, where x represents the copied text and y represents the subcard slot number.
Use the command output in
is 2.
[HP-probe]display hardware internal pci config 10:00.00 slot 5
<04:00.00> configuration space:
0000: dc 18 01 48 06 00 a0 02 12 00 80 02 00 ff 00 00
0010: 08 00 00 ec 08 00 00 ef 08 00 00 ed 00 00 00 ee
0020: 00 00 00 00 00 00 00 00 00 00 00 00 dc 18 01 48
... ... ... ...
If the first line in the command output is 0000: ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff, replace the subcard.
If the first line is not 0000: ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff, contact HP Support.
4.
If the problem persists, contact HP Support.

Related commands

This section lists the commands that you might use for troubleshooting the subcards.
Command
display hardware internal pci config bus:dev.func slot
slot-num
display hardware internal pci device slot slot-num
display hardware internal util slot slot-num nvlog start
num
more /var/log/trace.log
2
as an example. The copied text is 10:00.00 and the subslot number
Description
Displays information about the registers on the PCI
nodes.
Displays information about the PCI nodes.
Displays log messages in the nvlog.
Displays log messages in bash view.
37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hsr6800

Table of Contents