INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
WARNING: If the information in these
instructions is not followed exactly a fire
or explosion may result causing property
damage, personal injury or death.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapours and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical Switch.
• Do not use any phone in your building.
• Immediately call your gas supplier
from a neighbour's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier
call the fire department.
Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
This appliance may be installed in
an aftermarket permanently located,
manufactured home (USA only) or mobile home,
where not prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases unless a certified kit is used.
This appliance is suitable for installation in a
bedroom or bed sitting room.
Visit www. pacificenergy.net for the most up-to-date version of this manual
251115-44
CASCO / CAMDEN
INSTALLATION AND
OPERATING INSTRUCTIONS
MODEL: CASCO / CAMDEN
SERIES: B
DIRECT VENT FIREPLACES
CASC.BODYB - CMDN.BODYB
5055.634-B

Advertisement

Table of Contents
loading

Summary of Contents for Pacific energy CASCO

  • Page 1 This appliance is suitable for installation in a bedroom or bed sitting room. MODEL: CASCO / CAMDEN SERIES: B DIRECT VENT FIREPLACES Visit www. pacificenergy.net for the most up-to-date version of this manual CASC.BODYB - CMDN.BODYB...
  • Page 2: Table Of Contents

    INSTALLATION ............. 35 LIGHTING INSTRUCTIONS .......... 14 GLASS BURNER KIT ............ 36 DAMPER ADJUSTMENT ..........37 REPLACEMENT PARTS ..........38 CASCO AESTHETIC COMPONENTS ......38 CAMDEN AESTHETIC COMPONENTS .......38 WIRING DIAGRAM ............39 CASCO RATING LABEL ..........40 CAMDEN RATING LABEL ..........41 CASC.BODYB...
  • Page 3: Owner Information

    Owner Information Owner Information Important Note for the Commonwealth of Massachusetts From Massachusetts Rules and Regulations 248 CMR 5.08: (a) For all side wall horizontally vented gas fuelled equipment i finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied.
  • Page 4: Caution

    Owner Information Caution FOR YOUR SAFETY - Do not install or operate your Pacific Energy fireplace without first reading and understanding this manual. Any installation or operational deviation from the following instructions voids the Pacific Energy Warranty and may prove hazardous.
  • Page 5: Safety

    Owner Information Safety • Due to high temperatures, this gas appliance should be located out of traffic and away from furniture and draperies. • Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. • Young children should be carefully supervised when they are in the same room as the appli- ance.
  • Page 6: Congratulations On Your Purchase Of Apacific Energy Gas Fireplace

    Owner Information Congratulations on your purchase of a Paci c Energy Gas Fireplace. Your fireplace has been professionally installed by: Dealer name: __________________________________ Phone Number: __________________________________ If you discover any problems with your gas fireplace contact your dealer immediately to have the unit repaired.
  • Page 7: Remote Control Operation

    Owner Information Remote Control Operation System Description The Proflame 2 Remote Control System consists of two elements: 1. Proflame2 Transmitter. 2. Proflame2 Integrated Fireplace Control (IFC) board and a wiring harness to connect the IFC to the gas valve and stepper motor. Transmitter (Remote Control with LCD Display) The Proflame 2 Transmitter uses a streamline design with a simple button layout and informative LCD display (Figure 1).
  • Page 8: Ifc Module

    Owner Information IFC Module The Proflame 2 Integrated Fireplace Control (IFC) module (Figure 3) is a device that allows automatic ignition and pilot flame supervision, and commands the functions of the hearth Fireplace. It’s configured to control the ON/OFF main burner operation, giving the choice of both IPI (intermittent pilot ignition), and CPI (continuous pilot ignition) modes.
  • Page 9: Temperature Indication Display

    Owner Information Temperature indication Display With the system in the “OFF” position, press the Thermostat Key and the Mode Key at the same time. Look at the LCD screen on the transmitter to verify that a C or F is visible to the right of the Room Temperature display (Figure 6) or (Figure 7).
  • Page 10: Remote Flame Control

    Owner Information Remote Flame Control The Proflame2 has six (6) flame levels. With the system on, and the flame level at the maximum in the appliance, pressing the down arrow key once will reduce the flame height by one step until the flame is turned off.
  • Page 11: Comfort Fan Speed Control

    Owner Information Comfort Fan Speed Control If the Heater is equipped with a hot air circulating fan, the speed of the fan can be controlled by the Proflame 2 System. The fan speed can be adjusted through six (6) speeds. To activate this function use the Mode Key (Figure 1) to index to the fan control icon (Figure 13).
  • Page 12: Warnings And Cautions

    Owner Information Low Battery Power Detection Transmitter The life span of the remote control batteries depends on various factors: quality of the batteries used, the number of ignitions of the Heater, the number of changes to the room thermostat set point, etc.
  • Page 13: Maintenance

    Do not strike or otherwise impact the glass in any way that may cause it to break. If the glass becomes cracked or broken it must be replaced before using the fireplace. Replacement door can be obtained from your nearest Pacific Energy dealer. Do not substitute with any other type.
  • Page 14: Lighting Instructions

    Installer Information Installer Information Lighting Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: - Immediately call your gas supplier from a neighbour's phone. Follow If you do not follow these instructions exactly, a the gas supplier's instructions. fire or explosion may result causing property damage, - If you cannot reach your gas supplier, call the fire department.
  • Page 15: Fireplace Dimensions

    (560mm) 30 9/16" (775mm) 39 1/16" 22 9/16" (992mm) (573mm) 31 1/16" (789mm) Figure 16: Casco dimensions. Figure 17: Camden dimensions. NON-COMBUSTIBLE NON-COMBUSTIBLE FACING MATERIAL: FACING MATERIAL: 12” HIGH BY 1/2” THICK (MIN) WIDTH DETERMINED BY WIDTH OF FIREBOX. BY FIREBOX WIDTH 1/2"...
  • Page 16: Fireplace Framing Dimensions

    36 3/4" (1010mm) (933mm) 39 1/2" 31 1/2" (1003mm) (800mm) 20 7/8" 20 7/8" (530mm) (530mm) Figure 19: Casco framing dimensions. Figure 20: Camden framing dimension. 51 31/32" (1320mm) 17 5/32" (436mm) 17 5/32" (436mm) MINIMUM 2" (51mm) CLEARANCE 51 31/32"...
  • Page 17: Clearances To Combustibles

    6” “Louvered” and “Contured” refer to the style of “Fronts” avail- able to both the Casco and Camden replaces. Because of the different dimensions and BTU output of the two replaces, the distance between the bottom of the replace and the bot- tom of the mantels will vary depending on how far the mantel extends from the wall.
  • Page 18: Locating The Fireplace

    Due to high temperatures, do not locate this fireplace in areas of high traffic or near furniture or draperies. Figure 24: Casco Camden common locations. CASCO CAMDEN 31.5“...
  • Page 19: Venting

    For each additional 90° elbow, or an equal combination of elbows, reduce horizontal vent run by 2 feet. Ensure vent pipe is properly supported. Figure 26: Casco camden venting chart. CASC.BODYB 251115-44 5055.634-B CMDN.BODYB...
  • Page 20: Vent Terminal Minimum Clearances

    Installer Information Vent Terminal Minimum Clearances FIXED CLOSED OPEN- FIXED ABLE CLOSED OPEN- ABLE AREA WHERE TERMINAL GAS METER VENT TERMINAL AIR SUPPLY INLET IS NOT PERMITTED Figure 27: Vent terminal minimum clearances. *12 inches (30 cm) min. Clearances above grass, top of plants, wood, combustible veranda, porch, deck, or balcony. *12 inches (30 cm) min.
  • Page 21: Venting Components

    Installer Information Venting Components NOTE: Mixing venting components from different manufacturers is inadvisable. Description Metal-Fab® Security Selkirk DuraVent EXCELDirect® Sure-Seal Secure Vent™ Direct-Temp™ DirectVent Pro® Galvanize Black Galvanized Black Galvanized Black Galvanized Black Galvanized Black 6” Pipe Length 4DL6 4DL6B 4D6B SV4L6 SV4LB6...
  • Page 22: Plumbing And Electrical

    Installer Information Plumbing and Electrical Figure 31: Casco camden gas connection & electrical access panel. Gas connection To make the required electrical and gas connections, start by positioning the gas fireplace. Connect the gas supply line to the 1/2” fitting that extends out of the unit (Figure 31).
  • Page 23: Gas Supply

    Turn on the gas supply and check that all connections are tight and leak free. WARNING: The gas tray including gasket must be reinstalled after conversion/installation or servicing has been completed. Gas Pressure Check Please refer to following page for gas pressure testing procedure. Casco Gas pressure requirements Orifice Output AFUE...
  • Page 24: Gas Pressure Testing Procedure

    Installer Information Gas Pressure Testing Procedure Note: To test the gas pressure, turn off the gas supply to the appliance before loosening test point screws. Verify gas pressures with the fi replace lit and at the highest setting. 1. Remove bottom trim and locate the valve as seen in (Figure 32). 2.
  • Page 25: Surround Installation Instructions

    Installer Information Surround Installation Instructions Figure 34: Surround. Figure 35: Surround and lintel tab. The surround cover (Figure 34) attaches to the lintel once the decorative backing plate has been installed. The surround easily fits into place by connecting all four of its hooks to the lintels four tabs (Figure 35).
  • Page 26 Installer Information CAMDEN CASCO LOUVERED FRONT LOUVERED FRONT 32” 24” 23 1/2” 20 1/2” BRCA.18LFBKB - Black BDCD.30LFBKB - Black BRCA.18LFGYB - Grey BDCD.30LFGYB - Grey BRCA.18LFPCBKC - Powder coat Black BDCD.30LFPCBKC - Powder coat Black BRCA.18LFPCCUB - Powder coat Copper BDCD.30LFPCCUB - Powder coat Copper...
  • Page 27: Propane Conversion

    Phillips screwdriver and rotate the shutter until the open slots on both sides are completely open. Tighten the screw, and return the burner into position. Venturi Opening Propane Natural Gas 1/16” Open Casco 1/16” Open Camden Figure 41: Venturi shutter. CASC.BODYB 251115-44 5055.634-B...
  • Page 28: Door Installation/Removal

    Installer Information Door Installation/Removal Removal 1. Remove surround from lintel by lifting it from 4 tabs located on the lintel (Figure 42). 2. Locate and remove the two 3/8” bolts securing the bottom of door as seen in (Figure 43). 3.
  • Page 29: Fan Removal / Installation

    Installer Information Fan Removal / Installation 1. Make sure that the gas and electrical supply is shut off. 2. Locate and remove the two 3/8” bolts securing the bottom of door as seen in (“Figure 43: Accessing securring bolt.” on page 28). 3.
  • Page 30 Installer Information 5. Remove two screws which hold the back ledge (Figure 52) in place and remove. 6. Remove the approximately 25 screws hold the base plate (Figure 53) to the frame of the rebox. Figure 51: Removing the rear panel. Figure 52: Removing back ledge.
  • Page 31 Installer Information 8. The fan is located inside the opening and toward the rear of the rebox. A 3/8” nut (Figure 55) holds the fan assembly onto a threaded post. Remove the nut and gently extract the fan assembly from the re box (Figure 56). Be careful not to accidentally catch any other wires while the fan is being extracted.
  • Page 32: Panel Installation / Removal

    Installer Information Panel Installation / Removal Panel Installation Air De ector from burner kit needs to be installed NOTE: before panels. See Burner Kit Installation Left Right 1. Insert back panel so that it is sitting on ledge at Side Side the back of the rebox (Figure 59).
  • Page 33: Log Burner Kit Installation / Removal

    Installer Information Log Burner Kit Installation / Removal Air De ector Installation / Removal Installation Position the air de ector in the replace (Figure 62) and secure with two screws using a screwdriver. Screws Removal Remove the two screws (Figure 62) using a screwdriver, and remove the air de ector from replace.
  • Page 34: Traditional Log Set Installation / Removal

    Installer Information Traditional Log Set Installation / Removal Installation 1. Position rear log against the back rebox (Figure 67). 2. Position front log just behind the front burner tube (Figure 68). 3. Position log 3 (decorative log) with the thin end of the log resting on top of the right end of the front log(Figure 69).
  • Page 35: Rustic Log Set Installation / Removal

    Installer Information Rustic Log Set Installation / Removal INSTALLER INFORMATION Installation 1. Position rear logs1 and 2 against the back rebox (Figure 73). 2. Position front logs 3 and 4 between the front burner tubes (Figure 74). 3. Position side logs 5 & 6 (Figure 75). 4.
  • Page 36: Glass Burner Kit

    The glass burner plate comes with a collar for the pilot, screws to secure the burner tray to the rebox and and a bag of glass. Pilot Screw locations Collar Screw locations Figure 78: Casco camden glass tray. CASC.BODYB 5055.634-B 251115-44 CMDN.BODYB...
  • Page 37: Damper Adjustment

    Installer Information Damper Adjustment The Casco and Camden replaces both come with an adjustable damper that can limit the ow of intake air. This damper is located behind the air de ector at the rear of the inner rebox. Sometimes on installations that involve vertical venting con gurations over 10 feet in height, the intake air tends to accelerate down the vent causing hectic ame action.
  • Page 38: Replacement Parts

    Description Order Number 1. Casco Screen ........5002.610-A (for louvered front) 2. Casco Screen ........5002.615-A (for contoured front) 3. Camden Screen ........5002.710-A (for louvered front) 4. Camden Screen ........5002.715-A (for contoured front) 5. Complete Replacement Gas Tray ......GASC.BRNTRAYA 6.
  • Page 39: Wiring Diagram

    Installer Information Wiring Diagram Caution. Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Figure 80: Wiring diagram. CASC.BODYB 251115-44 5055.634-B CMDN.BODYB...
  • Page 40: Casco Rating Label

    Installer Information Casco Rating Label VENTED GAS FIREPLACE - NOT FOR USE LC- 208 WITH SOLID FUEL///FOYER AU GAZ À ÉVACUATION - NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE This Appliance is Equipped For Use With / ANSI Z21.88-2014 / CSA 2.33-2014 Vented Gas Fireplace Heaters Cet Appareil est Équipé...
  • Page 41: Camden Rating Label

    FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY / POUR UTILISATION UNIQUEMENT AVEC LES PORTES IN VERRE CERTIFIÉES AVEC L’APPAREIL Pacific Energy MINIMUM CLEARANCES TO COMBUSTIBLES / CLAIRANCES MINIMALES AVEC LES COMBUSTIBLE Left and Right side are determined when facing the front of the appliance. / Les côtés droit et gauche se déterminent Fireplace Products Ltd.
  • Page 42 Installer Information CASC.BODYB 5055.634-B 251115-44 CMDN.BODYB...
  • Page 43 Installer Information CASC.BODYB 251115-44 5055.634-B CMDN.BODYB...
  • Page 44 © 2015 Copyright Paci c Energy Fireplace Products LTD Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. For technical support, please contact your retailer Web site: www. pacificenergy.net 2975 Allenby Rd., Duncan, BC V9l 6V8...

This manual is also suitable for:

Camden

Table of Contents