Advertisement

Quick Links

INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
WARNING: If the information in these
instructions is not followed exactly a re
or explosion may result causing property
damage, personal injury or death.
FOR YOUR SAFETY
Do not store or use gasoline or other
ammable vapours and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical Switch.
• Do not use any phone in your building.
• Immediately call your gas supplier
from a neighbour's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier
call the re department.
Installation and service must be performed
by a quali ed installer, service agency or
the gas supplier.
This appliance may be installed in
an aftermarket permanently located,
manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type of
gas indicated on the rating plate. This appliance
is not convertible for use with other gases
unless a certi ed kit is used.
This appliance is suitable for installation in a
bedroom or bed sitting room.
210515-44
CASCO / CAMDEN
INSTALLATION AND
OPERATING INSTRUCTIONS
MODEL: CASCO / CAMDEN
SERIES: B
DIRECT VENT FIREPLACES
CASC.BODYB
CMDN.BODYB
5055.634-B

Advertisement

Table of Contents
loading

Summary of Contents for Pacific energy CASCO

  • Page 1 This appliance is not convertible for use with other gases unless a certi ed kit is used. This appliance is suitable for installation in a bedroom or bed sitting room. MODEL: CASCO / CAMDEN SERIES: B DIRECT VENT FIREPLACES 210515-44 CASC.BODYB 5055.634-B...
  • Page 2: Important Note For Massachusetts

    Important Note for the Commonwealth of Massachusetts: From Massachusetts Rules and Regulations 248 CMR 5.08: (a) For all side wall horizontally vented gas fuelled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above nished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satis ed.
  • Page 3: Table Of Contents

    Damper Adjustment ........38 Surround Installation Instructions ....25 Replacement Parts ........39 Venting ............19 Wiring Diagram ..........40 Vent Terminal Minimum Clearance ....20 Casco Rating Label ........41 Venting Components ........21 Camden Rating Label ........42 CASC.BODYB 210515-44 5055.634-B...
  • Page 4: Owners Information

    OWNER’S Caution INFORMATION FOR YOUR SAFETY - Do not install or operate your Paci c Energy replace without rst reading and understanding this manual. Any installation or operational deviation from the following instructions voids the Paci c Energy Warranty and may prove hazardous. This appliance and its individual shut off valve must be disconnected from gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).
  • Page 5: Safety

    OWNER’S Safety INFORMATION • Due to high temperatures, this gas appliance should be located out of traffic and away from furniture and draperies. • Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. •...
  • Page 6: First Fire

    OWNER’S INFORMATION Congratulations on your purchase of a Pacific Energy Gas Fireplace. Your fireplace has been professionally installed by: Dealer name: _____________________________ Phone Number: ___________________________ If you discover any problems with your gas fireplace contact your dealer immediately to have the unit repaired.
  • Page 7: Remote Control Operation

    OWNER’S Remote Control Operation INFORMATION System Description The Pro ame2 Remote Control System consists of two elements: Pro ame2 Transmitter. Pro ame2 Integrated Fireplace Control (IFC) board and a wiring harness to connect the IFC to the gas valve and stepper motor. Transmitter (Remote Control with LCD Display) The Pro ame2 Transmitter uses a streamline design with a simple button layout and informative LCD display (Fig.
  • Page 8: Ifc Module

    OWNER’S INFORMATION IFC Module The Pro ame2 Integrated Fireplace Control (IFC) module (Fig. 3) is a device that allows automatic ignition and pilot ame supervision, and commands the functions of the hearth Fireplace. It’s con gured to control the ON/OFF main burner operation, giving the choice of both IPI (intermittent pilot ignition), and CPI (continuous pilot ignition) modes.
  • Page 9 OWNER’S INFORMATION Temperature indication Display With the system in the “OFF” position, press the Thermostat Key and the Mode Key at the same time. Look at the LCD screen on the transmitter to verify that a C or F is visible to the right of the Room Temperature display. (Fig.
  • Page 10 OWNER’S INFORMATION Remote Flame Control The Pro ame2 has six (6) ame levels. With the system on, and the ame level at the maximum in the appliance, pressing the down arrow key once will reduce the ame height by one step until the ame is turned off.
  • Page 11 OWNER’S INFORMATION Comfort Fan Speed Control If the Heater is equipped with a hot air circulating fan, the speed of the fan can be controlled by the Pro ame2 System. The fan speed can be adjusted through six (6) speeds. To activate this function use the Mode Key (Fig.
  • Page 12: Warnings And Cautions

    OWNER’S INFORMATION Low Battery Power Detection Transmitter The life span of the remote control batteries depends on various factors: quality of the batteries used, the number of ignitions of the Heater, the number of changes to the room thermostat set point, etc.
  • Page 13: Maintenance

    OWNER’S Maintenance INFORMATION Turn off gas and electrical power supply (if applicable) and allow ample time for unit to cool before servicing appliance. It is recommended that the replace and its venting should be inspected at least once a year by a quali ed service person. Glass Door: Warning: Do not operate replace with glass door removed, cracked or broken.
  • Page 14: For Your Safety Read Before Lighting

    OWNER’S Lighting Instructions INFORMATION FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: - Immediately call your gas supplier from a neighbour's phone. Follow If you do not follow these instructions exactly, a the gas supplier's instructions. fire or explosion may result causing property damage, - If you cannot reach your gas supplier, call the fire department.
  • Page 15: Installer Information

    24 1/32" (636mm) (610mm) 30 9/16" 22 1/16" (775mm) (560mm) 39 1/16" (992mm) 22 9/16" (573mm) 31 1/16" (789mm) Figure 16: Casco Dimensions Figure 17: Camden Dimensions 1/2" FACING MATERIAL THICKNESS SURROUND BACKING FLANGE 2 1/2" ADJUSTMENT FOR DIFFERENT FACING MATERIAL...
  • Page 16 (530mm) (530mm) Figure 19: Casco Framing Figure 20: Camden Framing 51 31/32" (1320mm) 17 5/32" (436mm) 17 5/32" (436mm) MINIMUM 2" (51mm) CLEARANCE 51 31/32" (1320mm) Figure 21: Casco Corner Framing Figure 22: Camden Corner Framing CASC.BODYB 5055.634-B 210515-44 CMDN.BODYB...
  • Page 17: Clearances To Combustibles

    INSTALLER Clearances to Combustibles INFORMATION * MANTEL CLEARANCE CASCO CAMDEN LOUVERED CLEAN BROW LOUVERED CLEAN BROW 12” 15” 26” 12” 15” 12” 12” 14.5” 24.5” 12” 14.5” 12” 12” 15” 23” 12” 14” 12” ** MANTEL DEPTH 12” 9” 6”...
  • Page 18: Locating The Fireplace

    Due to high temperatures, do not locate this fireplace in areas of high traffic or near furniture or draperies. Figure 25: Common Installation Location CASCO CAMDEN 31.5 “...
  • Page 19: Venting

    INSTALLER Venting INFORMATION Note: The intake damper positions speci ed in this chart were set in a controlled testing environment, and serve as a general guideline for installations. Every venting con guration is different, and the damper setting may need slight adjustment from this chart.
  • Page 20: Vent Terminal Minimum Clearance

    INSTALLER Vent Terminal Minimum Clearances INFORMATION Figure 28: Vent terminal minimum clearances. This fireplace is certified for use with 4” x 6-5/8”coaxial venting components only. It is permitted to only use certified venting for this appliance. Including certified coaxial flexible venting. Figure 29: Venting components CASC.BODYB 5055.634-B...
  • Page 21: Venting Components

    INSTALLER Venting Components INFORMATION NOTE: Mixing venting components from different manufacturers is inadvisable. Figure 30: 4”x6-5/8” Rigid Piping Cross Reference Chart Figure 31: 4”x6-5/8” Rigid Pipe Components Cross Reference Chart CASC.BODYB 210515-44 5055.634-B CMDN.BODYB...
  • Page 22: Plumbing And Electrical

    INSTALLER Plumbing and Electrical INFORMATION Figure 32: Gas and Electrical Connections Gas connection To make the required electrical and gas connections, start by positioning the gas replace. Connect the gas supply line to the 1/2” tting that extends out of the unit as seen in Figure 32.
  • Page 23: Gas Supply

    Turn on the gas supply and check that all connections are tight and leak free. WARNING: The gas tray including gasket must be reinstalled after conversion/installation or servicing has been completed. Gas Pressure Check Please refer to following page for gas pressure testing procedure. Casco Gas pressure requirements Ori ce Output AFUE 1.98mm...
  • Page 24: Gas Pressure Testing Procedure

    INSTALLER Gas Pressure Testing Procedure INFORMATION Note: To test the gas pressure, turn off the gas supply to the appliance before loosening test point screws. Verify gas pressures with the fireplace lit and at the highest setting. 1. Remove bottom trim and locate the valve as seen in Figure 33. 2.
  • Page 25: Surround Installation Instructions

    INSTALLER Surround Installation Instructions INFORMATION Figure 35: Door Figure 36: Surround and lintel tab The surround cover (Fig.35) attaches to the lintel once the decorative backing plate has been installed. The surround easily ts into place by connecting all four of its hooks to the lintels four tabs (Fig.36).
  • Page 26 INSTALLER INFORMATION CASCO CAMDEN 32” 24” 23 1/2” 20 1/2” BRCA.18LFBKB - Louvered / Black BDCD.30LFBKB - Louvered / Black BRCA.18LFGYB - Louvered / Grey BDCD.30LFGYB - Louvered / Grey 24” 32” 20 1/2” 23 1/2” BRCA.18CFBKB - Contoured / Black BDCD.30CFBKB - Contoured / Black...
  • Page 27: Propane Conversion

    INSTALLER Propane Conversion INFORMATION Before starting the conversion make sure to shut off the gas supply to the unit and allow replace to cool to room temperature. To convert the gas replace from natural gas to propane the (GASC.LPKIT) kit is required. This kit comes with new pilot and burner ori ces as well as a new pressure modulator for the valve.
  • Page 28: Adjustable Leveling Bolts

    INSTALLER Adjustable leveling bolts INFORMATION Adjustable leveling bolts This replace comes with two leveling bolts used to adjust the angle of the front of the replace relative to the wall in which it’s installed. The bolts are not pre-installed and can be found in a separate plastic bag. Care in measuring should be exercised if using the bolts as the replace will be required to be removed each time an...
  • Page 29: Battery Holder Installation

    INSTALLER Battery Holder Installation INFORMATION A new battery holder bracket replaces the older one in the series A replaces. The older one (Fig. 45) was riveted into place while the new series B bracket (Fig. 46) is screwed into place. Figure 45: Older riveted bracket.
  • Page 30: Fan Installation/ Removal

    INSTALLER Fan Removal / Installation INFORMATION Make sure that the gas and electrical supply is shut off. Locate and remove the two 3/8” bolts securing the bottom of door as seen in Figure 48. Figure 48 Tilt the bottom of the door away from the appliance and lift the door off. Media Removal Removal ( gures 49 &...
  • Page 31 INSTALLER INFORMATION Removing the Burner and Burner tray. 1. Remove the screw holding the burner to the burner tray (Figure 51). 2. Remove two screws from the upper baffle and remove (Fig. 52) Figure 51 Figure 52 Figure 53 3. Remove two screws from the burner plate (Fig. 53) and remove. 4.
  • Page 32 INSTALLER INFORMATION Figure 56 Figure 57 5. Remove two screws which hold the back ledge (Fig.56) in place and remove. 6. Remove the approximately 25 screws hold the base plate (Fig. 57) to the frame of the rebox. 7. Gently remove the base plate (Fig. 58) and set aside to the right hand side of the rebox.
  • Page 33 INSTALLER INFORMATION 8. The fan is located inside the opening and toward the rear of the rebox. A 3/8” nut holds the fan assembly onto a threaded post. Remove the nut and gently extract the fan assembly from the re box (Fig. 60) Be careful not to accidentally catch any other wires while the fan is being extracted.
  • Page 34: Panel Installation/Removal

    INSTALLER Panel Installation / Removal INFORMATION Panel Installation NOTE: Air De ector from burner kit needs to be installed before panels. See Burner Kit Installation 1. Insert back panel so that it is sitting on ledge at the back of the firebox as shown in Figure 63. 2.
  • Page 35: Log Burner Kit Installation/Removal

    INSTALLER Log Burner Kit Installation / Removal INFORMATION Air De ector Installation / Removal Installation Position the air de ector in the replace as seen in Figure 66 and secure with two screws using a screwdriver. Removal Remove the two screws seen in Figure 66 using a screwdriver, and remove the air de ector from replace.
  • Page 36: Log Set Installation/Removal

    INSTALLER Log Set Installation / Removal INFORMATION Installation 1. Position rear log against the back rebox as seen in Figure 71. 2. Position front log just behind the front burner tube as seen in Figure 72. 3. Position log 3 with the thin end of the log resting on top of the right end of the front log as seen in Figure 73.
  • Page 37: Rustic Log Set Installation/Removal

    INSTALLER Rustic Log Set Installation / Removal INFORMATION Installation 1. Position rear logs #1 and #2 against the back rebox as seen in Figure 77. 2. Position front logs #3 and #4 between the front burner tubes as seen in Figure 78. 3.
  • Page 38: Damper Adjustment

    INSTALLER Damper Adjustment INFORMATION The Casco and Camden replaces both come To adjust the damper, loosen the two screws that with an adjustable damper that can limit hold the air de ector in place. Slide the damper the ow of intake air. This damper is located...
  • Page 39: Replacement Parts

    INSTALLER Replacement Parts INFORMATION Description Order Number Casco Screen ..............BRCA.SCRNA 2. Camden Screen ..............BDCD.SCRNA 3. Complete Replacement Gas Tray ........ GASC.BRNTRAYA Replacement Remote Control .......... GASC.CNTRLA 5. Replacement Blower............GASC.SBLOWA 6. Replacement Blower............GASC.LBLOWA Casco Aesthetic Components Camden Aesthetic Components CASC.BODYB...
  • Page 40: Wiring Diagram

    INSTALLER Wiring Diagram INFORMATION Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Figure 83: Wiring Diagram CASC.BODYB 5055.634-B 210515-44 CMDN.BODYB...
  • Page 41: Casco Rating Label

    INSTALLER Casco Rating Label INFORMATION VENTED GAS FIREPLACE - NOT FOR USE LC- 208 WITH SOLID FUEL///FOYER AU GAZ À ÉVACUATION - NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE This Appliance is Equipped For Use With / ANSI Z21.88-2014 / CSA 2.33-2014 Vented Gas Fireplace Heaters Cet Appareil est Équipé...
  • Page 42: Camden Rating Label

    FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY / POUR UTILISATION UNIQUEMENT AVEC LES PORTES IN VERRE CERTIFIÉES AVEC L’APPAREIL Pacific Energy MINIMUM CLEARANCES TO COMBUSTIBLES / CLAIRANCES MINIMALES AVEC LES COMBUSTIBLE Left and Right side are determined when facing the front of the appliance. / Les côtés droit et gauche se déterminent Fireplace Products Ltd.
  • Page 43 INSTALLER INFORMATION CASC.BODYB 210515-44 5055.634-B CMDN.BODYB...
  • Page 44 © 2015 Copyright Paci c Energy Fireplace Products LTD Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. For technical support, please contact your retailer Web site: www. paci cenergy.net 2975 Allenby Rd., Duncan, BC V9l 6V8...

This manual is also suitable for:

Camden