6 Electrical installation
A
a
A
d
c
a
Top side
b
Left side
c
Bottom side
d
Right side
3 Mount the front plate.
▪ Align the positioning pins and push the front plate onto the
rear plate until it moves into place with a click.
▪ The connector pins are automatically inserted correctly.
a
b
a
Positioning pins
b
Connector pins
Opening the user interface after it is installed
If you need to open the user interface after it is installed, proceed as
follows:
1 Remove the WLAN cartridge and USB memory stick (if any).
2 Push the rear plate on each of the 4 spots where the snap-fits
are located.
Installation manual
24
B
B
b
X1B
a
6.3.6

To connect the shut-off valve

INFORMATION
Shut-off valve usage example. In case of one LWT zone,
and a combination of underfloor heating and heat pump
convectors, install a shut-off valve before the underfloor
heating to prevent condensation on the floor during cooling
operation.
Wires: 2×0.75 mm²
Maximum running current: 100 mA
230 V AC supplied by PCB
1 Access the electrical connections. See
electrical wiring to the outdoor
2 Connect the valve control cable to the appropriate terminals as
shown in the illustration below.
NOTICE
Only connect NO (normally open) valves.
180°
3
4
3 Fix the cable with cable ties to the cable tie mountings.
EBLA04~08E2V3+E23V3 + EDLA04~08E2V3+E23V3
"6.3.1  To connect the
unit" [ 4  17].
X2M.3
M2S
X2M.4
(NO)
X2M
Daikin Altherma 3 M
4P685229-1D – 2022.10