2. Description of the Programming Menus - Address Tables:
Menu
Description
1
Changing own access code
Memory LOG file review
2
Use Button "2" for additional information;
Use button "1" to return to date and time showing screen.
3
Chime setting
Zone bypassing
4
Menu
Description
Changing user access codes
01
Memory LOG file review
02
Use Button "2" for additional information;
Use button "1" to return to date and time showing screen.
03
Chime setting
04
Zone bypassing
05
Engineer access
06
Attributes for User rights
07
User areas
08
User names
09
User Time Slots
10
User Porxi card attributes
11
Adding / Deleting proxi cards
13
Cloning of user attributes and
rights
14
Setting the time
15
Setting the date
16
Remote access
17
Remote access attributes
18
Manual test for communication
Function of button
21
of BRAVO RC key fob
90
Buzzer level
Brightness of the buttons and
91
display backlit
Scroll speed setting
92
Sensitive buttons
93
backlit
Submenu
Settings
Press button "0" to delete the current code,
enter new access code and confirm
Event code;
DISABLE - The chime is disabled
ENABLE - The chime is enabled
Enter zone
NOT BYPASSED - The zone is not bypassed.
number
BYPASSED - The zone is bypassed
Submenu
Settings
Enter user
Press button "0" to delete the current code,
number
enter new access code and confirm
Event code;
DISABLE - The chime is disabled
ENABLE - The chime is enabled
Enter zone
NOT BYPASSED - The zone is not bypassed.
number
BYPASSED - The zone is bypassed
DISABLE - The engineer access is disabled.
ENABLE - The engineer access is enabled.
Enter user
1 - Disarming
number
2 - Stay/Sleep ARM
3 - Bypass
4 - Programming
8 - Manager
Enter area numbers associated for the
Enter user
respective user number.
number
Enter user name up to 16 symbols -
Enter user
use the digit buttons for text enter.
number
Enter time slot number (1-8) associated for the
Enter user
respective user number.
number
Enter user
1 - Disarming; 2 & 3 - Arming
number
(2+3 = Sleep; 2 * = Stay; * 3 = Full)
Enter user
Place the card in front of the proxi reader until
number
a confirmation signal is heard.
To delete a card press and hold the "0" button.
Enter in sequence a user source code, then
first user code to clone, and at the end - the
last user code to clone.
Enter actual hour and minutes using time
format [HH:MM].
Enter actual date using format [DD/MM/YY].
Enter the permissible number of invalid access
codes for remote access - value 000 to 255.
1 - Disarm; 2 - ARM; 3 - Codes Access;
4 - Programming; 6 - Bypass
Sending of test messages to central monitoring
station.
Enter user
0 - Not used; 1 - Sleep ARM; 2 - Stay ARM;
number
3 - Fire alarm; 4 - Medical alarm; 5 - Police alarm
Adjust the buzzer volume level from 1 to 4.
Use the arrows to increase or decrease volume.
Adjust the backlit level from 1 to 7.
Use the arrows to increase or decrease value.
Enter the scroll speed for displaying text
messages on the LCD - 1 to 7.
ON - The backlit is enabled.
OFF - The backlit is disabled.
Default
Event text description
with date and time
DISABLED
Default
Manager - 0000
Users - No
Event text description
with date and time
DISABLED
ENABLED
1, 2, 3, 4
Manager -
All rights
Users -
1, 2, 3, 4, 8
Partial Rights
Manager:
All Areas
Users:
Area 1
USER XX
0
1, 2, 3
(Sleep Arming)
00:00
01/01/12
10
1, 2, 3, 4, 6
0
2
4
3
OFF