Time Code Operation Mode
Set the time code operation in [Main Menu] B [TC/
UB] B [TC Generator].
(A P100 [ TC Generator ] )
Setting
Free Run(Ext) This mode synchronizes another
camera recorder connected to the
[TC] terminal. The time code
operates in the run mode at all
times regardless of the recording
status.
It continues to run even when the
power of the camera recorder is
turned off.
Free Run
The time code operates in the run
mode at all times regardless of the
recording status.
It continues to run even when the
power of the camera recorder is
turned off.
Rec Run
The time code operates in the run
mode during recording. It
continues to run in the order of the
recorded clips as long as the SD
card is not replaced. If the SD card
is removed and recording is made
on another card, time code will be
recorded on the new card from
where it was left off in the previous
card.
Regen
The time code operates in the run
mode during recording. When the
SD card is replaced, the last time
code recorded on the card is read
and recorded on a new card so that
the time code continues in running
order.
(A P64 [Setting Time Code] )
Memo :
When [Main Menu] B [System] B [Record
0
Set] B [Rec Mode] is set to "Variable Frame",
"Interval Rec" or "Frame Rec", and [TC
Generator] is set to "Free Run" or "Free
Run(Ext)", Rec Run is activated.
When [Main Menu] B [System] B [Record
0
Set] B [Record Format] B [Format] is set to
"AVCHD", Pre Rec enters Free Run mode.
(A P109 [ Format ] )
Description
Setting Time Code
Generator
Presetting the Time Code
Time code and user's bit data generated from the
internal time code generator are recorded.
This section describes how to set [TC/UB] B [TC
Preset].
(A P101 [ TC Preset ] )
Memo :
When [Main Menu] B [System] B [Record
0
Set] B [Record Format] B [Frame & Bit Rate] is
set to "50i(HQ)", "50i(SP)", "50p(HQ)",
"50p(SP)", "25p(HQ)", "24p(HQ)", or "50i",
settings cannot be made in "Drop".
(A P109 [ Frame & Bit Rate ] )
You can configure the setting without accessing
0
the [TC/UB] menu screen.
(A P65 [Setting Time Code without Opening
the Menu] )
Required Settings Before Preset
1 Set [TC/UB] B [TC Generator] to "Rec Run"
or "Free Run".
(A P100 [ TC Generator ] )
[Rec Run]:
0
Preset data in the time code generator
operates in run mode during recording
mode. Set this when recording continuous
time code in connecting frames.
[Free Run]:
0
Time code starts to operate in run mode from
the preset time in the time code generator.
2 Select the framing mode for the time code
generator (only when the frame rate setting
is "60" or "30").
Set using [Main Menu] B [TC/UB] B [Drop
Frame].
(A P101 [ Drop Frame ] )
[Drop]:
0
Sets the run mode of the time code generator
to drop frame mode. Use this setting when
placing emphasis on the recording time.
[Non Drop]:
0
Sets the run mode of the time code generator
to non-drop frame mode. Use this setting
when placing emphasis on the number of
frames.